An 11- to 15-year clinical outcome study of the Advance Medial Pivot total knee arthroplasty: Pivot knee arthroplasty
Ημερομηνία
2016Γλώσσα
en
Λέξη-κλειδί
Επιτομή
Aims The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the longterm results obtained with this prosthesis by extending a previous evaluation. Patients and Methods We retrospectively evaluated prospectively collected data from 225 consecutive patients (41 men and 184 women; mean age at surgery 71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both subjective and objective) and radiological outcome were assessed. Pre- and postoperative clinical and radiographic data were available at regular intervals for all patients. A total of ten patients (4.4%; ten TKAs) were lost to follow-up. Results Survival analysis at 15 years showed a cumulative success rate of 97.3% (95% confidence interval (CI) 96.7 to 97.9) for revision for any reason, of 96.4% (95% CI 95.2 to 97.6) for all operations, and 98.8% (95% CI 98.2 to 99.4) for aseptic loosening as an end point. Three TKAs (1.06%) were revised due to aseptic loosening, two (0.7%) due to infection, one (0.35%) due to instability and one (0.35%) due to a traumatic dislocation. All patients showed a statistically significant improvement on the Knee Society Score (p = 0.001), Western Ontario and McMaster University Osteoarthritis Index (p = 0.001), Short Form-12 (p = 0.01),and Oxford Knee Score (p = 0.01). A total of 207 patients (92%) were able to perform age appropriate activities with a mean flexion of the knee of 117° (85° to 135°) at final follow-up. Conclusion This study demonstrates satisfactory functional and radiographic long-term results for this implant. © 2016 The British Editorial Society of Bone & Joint Surgery.
Collections
Related items
Showing items related by title, author, creator and subject.
-
A 13- to 16-year clinical and radiological outcome study of the genesis II cruciate retaining total knee arthroplasty with an oxidised zirconium femoral component
Papasoulis E., Karachalios T. (2019)Purpose: The Genesis II Total Knee Arthroplasty with an oxidized zirconium (OxiniumTM) femoral component (Smith & Nephew, Memphis, TN, USA) was introduced in an attempt to reduce polyethylene wear and osteolysis. Methods: ... -
Genesis 1 posterior cruciate-retaining total knee arthroplasty with asymmetric tibial tray: An 18-to-26-year long-term clinical outcome study
Georgaklis V.A., Karachalios T., Makridis K.G., Badras S.L., Palaiochorlidis I.S., Malizos K.N., Badras L.S. (2019)Background: To present the long-term clinical and radiological outcomes of the Genesis I posterior cruciate-retaining total knee arthroplasty (TKA) (Smith & Nephew Orthopaedics, Memphis, TN, USA) (one of the first designed ... -
Multicenter Mid-term Results After Endovascular Aortic Aneurysm Repair with the Incraft® Device
Georgiadis G.S., Chatzigakis P.K., Kouvelos G., Argyriou C., Kopadis G.C., Georgakarakos E.I., Matsagkas M. (2021)Objectives: Durability after endovascular aortic aneurysm repair (EVAR) is considered an ongoing topic of investigation and was always a point of concern with smaller profile devices. Recently released five-year clinical ...