An 11- to 15-year clinical outcome study of the Advance Medial Pivot total knee arthroplasty: Pivot knee arthroplasty

Thumbnail
Autor
Karachalios Th., Varitimidis S., Bargiotas K., Hantes M., Roidis N., Malizos K.N.
Fecha
2016
Language
en
DOI
10.1302/0301-620X.98B8.36208
Materia
adult
aged
Article
clinical outcome
controlled study
follow up
human
knee function
knee osteoarthritis
knee prosthesis
knee radiography
Knee Society Score
major clinical study
Oxford Knee Score
priority journal
prosthesis infection
prosthesis loosening
retrospective study
rheumatoid arthritis
Short Form 12
survival analysis
total knee arthroplasty
Western Ontario and McMaster Universities Osteoarthritis Index
adverse effects
devices
diagnostic imaging
female
hip
knee prosthesis
knee replacement
male
middle aged
Osteoarthritis, Hip
Pain, Postoperative
patient satisfaction
prospective study
prosthesis design
prosthesis failure
Prosthesis-Related Infections
treatment outcome
very elderly
Aged
Aged, 80 and over
Arthroplasty, Replacement, Knee
Female
Follow-Up Studies
Hip Joint
Humans
Knee Prosthesis
Male
Middle Aged
Osteoarthritis, Hip
Pain, Postoperative
Patient Satisfaction
Prospective Studies
Prosthesis Design
Prosthesis Failure
Prosthesis-Related Infections
Retrospective Studies
Treatment Outcome
British Editorial Society of Bone and Joint Surgery
Mostrar el registro completo del ítem
Resumen
Aims The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the longterm results obtained with this prosthesis by extending a previous evaluation. Patients and Methods We retrospectively evaluated prospectively collected data from 225 consecutive patients (41 men and 184 women; mean age at surgery 71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both subjective and objective) and radiological outcome were assessed. Pre- and postoperative clinical and radiographic data were available at regular intervals for all patients. A total of ten patients (4.4%; ten TKAs) were lost to follow-up. Results Survival analysis at 15 years showed a cumulative success rate of 97.3% (95% confidence interval (CI) 96.7 to 97.9) for revision for any reason, of 96.4% (95% CI 95.2 to 97.6) for all operations, and 98.8% (95% CI 98.2 to 99.4) for aseptic loosening as an end point. Three TKAs (1.06%) were revised due to aseptic loosening, two (0.7%) due to infection, one (0.35%) due to instability and one (0.35%) due to a traumatic dislocation. All patients showed a statistically significant improvement on the Knee Society Score (p = 0.001), Western Ontario and McMaster University Osteoarthritis Index (p = 0.001), Short Form-12 (p = 0.01),and Oxford Knee Score (p = 0.01). A total of 207 patients (92%) were able to perform age appropriate activities with a mean flexion of the knee of 117° (85° to 135°) at final follow-up. Conclusion This study demonstrates satisfactory functional and radiographic long-term results for this implant. © 2016 The British Editorial Society of Bone & Joint Surgery.
URI
http://hdl.handle.net/11615/74330
Colecciones
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]

Ítems relacionados

Mostrando ítems relacionados por Título, autor o materia.

  • Thumbnail

    A 13- to 16-year clinical and radiological outcome study of the genesis II cruciate retaining total knee arthroplasty with an oxidised zirconium femoral component 

    Papasoulis E., Karachalios T. (2019)
    Purpose: The Genesis II Total Knee Arthroplasty with an oxidized zirconium (OxiniumTM) femoral component (Smith & Nephew, Memphis, TN, USA) was introduced in an attempt to reduce polyethylene wear and osteolysis. Methods: ...
  • Thumbnail

    Genesis 1 posterior cruciate-retaining total knee arthroplasty with asymmetric tibial tray: An 18-to-26-year long-term clinical outcome study 

    Georgaklis V.A., Karachalios T., Makridis K.G., Badras S.L., Palaiochorlidis I.S., Malizos K.N., Badras L.S. (2019)
    Background: To present the long-term clinical and radiological outcomes of the Genesis I posterior cruciate-retaining total knee arthroplasty (TKA) (Smith & Nephew Orthopaedics, Memphis, TN, USA) (one of the first designed ...
  • Thumbnail

    Multicenter Mid-term Results After Endovascular Aortic Aneurysm Repair with the Incraft® Device 

    Georgiadis G.S., Chatzigakis P.K., Kouvelos G., Argyriou C., Kopadis G.C., Georgakarakos E.I., Matsagkas M. (2021)
    Objectives: Durability after endovascular aortic aneurysm repair (EVAR) is considered an ongoing topic of investigation and was always a point of concern with smaller profile devices. Recently released five-year clinical ...