Logo
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • English 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Login
View Item 
  •   University of Thessaly Institutional Repository
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • View Item
  •   University of Thessaly Institutional Repository
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
Institutional repository
All of DSpace
  • Communities & Collections
  • By Issue Date
  • Authors
  • Titles
  • Subjects

AMBIENT DOSE EQUIVALENT RECEIVED at 15 MV LINAC ENVIRONMENTS DUE to PHOTONEUTRONS CONTAMINATION

Thumbnail
Author
Vagena E., Katsaras P., Theodorou K., Stoulos S.
Date
2018
Language
en
DOI
10.1093/rpd/ncy104
Keyword
analysis
body burden
device failure analysis
equipment design
Greece
human
magnetic and electromagnetic equipment
neutron
occupational exposure
photon
procedures
radiation dose
radiation protection
radiometry
Body Burden
Equipment Design
Equipment Failure Analysis
Greece
Humans
Neutrons
Occupational Exposure
Particle Accelerators
Photons
Radiation Dosage
Radiation Protection
Radiometry
Oxford University Press
Metadata display
Abstract
Mapping of the photoneutron spectrum and flux performed at several positions over the treatment table of a 15 MV medical linac. Neutron activation technique has been applied to obtain the neutron spectra in the mixed I3 -n field. Thick foils have been used due to the low neutron flux and the measurements were unfolded using the MINUIT minimizer. GEANT4 code simulations have been performed to reproduce the photoneutrons' spectrum and estimate the flux along the treatment table. The mixed radiation field around medical linear accelerator was evaluated and the variation of the ambient dose equivalent over the treatment table was estimated. Photoneutrons' ambient dose equivalent inside the irradiation field estimated as 0.56 ± 0.05 while the peripheral as 0.42 ± 0.04 mSv Gy -1 . The effective dose inside the irradiation field is ranged between 0.004 and 0.049 while the peripheral up to 0.035 mSv Gy -1 . © The Author(s) 2018. Published by Oxford University Press. All rights reserved.
URI
http://hdl.handle.net/11615/80322
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister (MyDspace)
Help Contact
DepositionAboutHelpContact Us
Choose LanguageAll of DSpace
EnglishΕλληνικά
htmlmap