Hemodynamic profile of two aortic endografts accounting for their postimplantation position

Thumbnail
Auteur
Raptis A., Xenos M., Georgakarakos E., Kouvelos G., Giannoukas A., Matsagkas M.
Date
2017
Language
en
DOI
10.1115/1.4035687
Sujet
Blood
Blood vessels
Computerized tomography
Hemodynamics
Image processing
Image reconstruction
Patient treatment
Repair
Shear flow
Shear stress
Abdominal aortic aneurysms
Computational approach
Computed tomography scan
Displacement force
Morphological characteristic
Operating principles
Regions of interest
Spatial fluctuation
Computational fluid dynamics
abdominal aortic aneurysm
aortic aneurysm endovascular graft
aortic graft
Article
blood flow velocity
clinical article
computational fluid dynamics
computer assisted tomography
endovascular aneurysm repair
hemodynamics
human
image reconstruction
implantation
morphological trait
preoperative period
shear stress
American Society of Mechanical Engineers (ASME)
Afficher la notice complète
Résumé
Endovascular aneurysm repair (EVAR) is a clinically effective technique for treating anatomically eligible abdominal aortic aneurysms (AAAs), involving the deployment of an endograft (EG) that is designed to prevent blood leakage in the aneurysmal sac. While most EGs have equivalent operating principles, the hemodynamic environment established by different EGs is not necessarily the same. So, to unveil the post-EVAR hemodynamic properties, we need an EG-specific computational approach that currently lacks from the literature. Endurant and Excluder are two EGs with similar pre-installation designs. We assumed that the flow conditions in the particular EGs do not vary significantly. The hypothesis was tested combining image reconstructions, computational fluid dynamics (CFD), and statistics, taking into account the postimplantation position of the EGs. Ten patients with Endurant EGs and ten patients with Excluder EGs were included in this study. The two groups were matched with respect to the preoperative morphological characteristics of the AAAs. The EG models are derived from image reconstructions of postoperative computed tomography scans. Wall shear stress (WSS), displacement force, velocity, and helicity were calculated in regions of interest within the EG structures, i.e., the main body, the upper and lower part of the limbs. Excluder generated higher WSS compared to Endurant, especially on the lower part of the limbs (p=0.001). Spatial fluctuations of WSS were observed on the upper part of the Excluder limbs. Higher blood velocity was induced by Excluder in all the regions of interest (p=0.04, p=0.01, and p=0.004). Focal points of secondary flow were detected in the main body of Endurant and the limbs of Excluder. The displacement force acting on the lower part of the Excluder limbs was stronger compared to the Endurant one (p=0.03). The results showed that two similar EGs implanted in similar AAAs can induce significantly different flow properties. The delineation of the hemodynamic features associated with the various commercially available EGs could further promote the personalization of treatment offered to aneurysmal patients and inspire ideas for the improvement of EG designs in the future. © 2017 by ASME.
URI
http://hdl.handle.net/11615/78462
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]

Related items

Showing items related by title, author, creator and subject.

  • Thumbnail

    Anatomical Differences Between Intact and Ruptured Large Abdominal Aortic Aneurysms 

    Spanos K., Nana P., Kouvelos G., Mpatzalexis K., Matsagkas M., Giannoukas A.D. (2020)
    Purpose: To compare different anatomical characteristics between intact and ruptured large abdominal aortic aneurysms (rAAA >80 mm) with the goal of refining the process of estimating rupture risk. Materials and Methods: ...
  • Thumbnail

    Endovascular Treatment of a Saccular Thoracic Aortic Aneurysm with Contained Rupture Inside a Para-aortic Mass 

    Spanos K., Giannoukas A.D. (2016)
    [No abstract available]
  • Thumbnail

    Management of Descending Thoracic Aortic Diseases: Similarities and Differences Among Cardiovascular Guidelines 

    Spanos K., Nana P., Behrendt C.-A., Kouvelos G., Panuccio G., Heidemann F., Matsagkas M., Debus E.S., Giannoukas A., Kölbel T. (2021)
    Cardiovascular societies have developed recommendations regarding the management of thoracic aortic diseases. While improvements in treatment have been observed during the past decade in regard to patient selection, thoracic ...