• English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Deutsch 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Einloggen
Dokumentanzeige 
  •   DSpace Startseite
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Dokumentanzeige
  •   DSpace Startseite
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.
Gesamter Bestand
  • Bereiche & Sammlungen
  • Erscheinungsdatum
  • Autoren
  • Titeln
  • Schlagworten

Surgical and radiological anatomy of the medial patellofemoral ligament: A magnetic resonance imaging and cadaveric study

Thumbnail
Autor
Raoulis V., Fyllos A., Klontzas M.E., Chytas D., Mitrousias V., Banios K., Maris T.G., Karantanas A.H., Zibis A.
Datum
2021
Language
en
DOI
10.3390/diagnostics11112076
Schlagwort
article
cadaver
controlled study
dissection
human
intermethod comparison
knee
ligament
nuclear magnetic resonance imaging
patella
quadriceps tendon
surgical anatomy
MDPI
Zur Langanzeige
Zusammenfassung
The purpose of this study was to compare the measurement of several anatomical features of the medial patellofemoral ligament (MPFL) between magnetic resonance imaging (MRI) and by direct fashion during dissection. We hypothesized that the measurements between these two techniques would agree. MRI of 30 fresh-frozen cadaveric knees was followed by dissection. MPFL patella and femoral attachment were evaluated; their shape, length, and width were measured; and measurements were compared. MRI was deemed unreliable for the determination of several of the aforementioned anatomical features. Important findings include: (a) observations on MPFL attachment at medial patella side and attachment to quadriceps were identical between dissection and MRI; (b) average width at patella insertion was significantly different between the two methods (p = 0.002); and (c) an attachment to the quadriceps tendon was present in 20/30 specimens and d. detailed measurements of a thin, non-linear, and three-dimensional structure, such as the MPFL, cannot be performed on MRI, due to technical difficulties. This anatomical radiological study highlights the shape, anatomical measurements (length and width), and attachment of the MPFL using a relatively large cadaveric sample and suggests that MRI is not reliable for detailed imaging of its three-dimensional anatomy. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
URI
http://hdl.handle.net/11615/78453
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

EinloggenRegistrieren
Help Contact
DepositionAboutHelpKontakt
Choose LanguageGesamter Bestand
EnglishΕλληνικά
htmlmap