Logo
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • English 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Login
View Item 
  •   University of Thessaly Institutional Repository
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • View Item
  •   University of Thessaly Institutional Repository
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
Institutional repository
All of DSpace
  • Communities & Collections
  • By Issue Date
  • Authors
  • Titles
  • Subjects

Left atrial diameter thresholds and new incident atrial fibrillation in embolic stroke of undetermined source

Thumbnail
Author
Perlepe K., Sirimarco G., Strambo D., Eskandari A., Karagkiozi E., Vemmou A., Koroboki E., Manios E., Makaritsis K., Vemmos K., Michel P., Ntaios G.
Date
2020
Language
en
DOI
10.1016/j.ejim.2020.01.002
Keyword
anticoagulant agent
antithrombocytic agent
adult
aged
anticoagulant therapy
Article
atrial fibrillation
cerebrovascular accident
clinical trial (topic)
comparative study
diagnostic test accuracy study
diagnostic value
disease association
disease registry
embolic stroke of undetermined source
embolic stroke of undetermined source
female
follow up
heart left atrium
human
major clinical study
male
negative prognostic value
positive prognostic value
predictive value
prognosis
recurrence risk
recurrent disease
retrospective study
sensitivity and specificity
Youden index
atrial fibrillation
brain embolism
cerebrovascular accident
complication
prospective study
risk factor
Atrial Fibrillation
Embolic Stroke
Humans
Intracranial Embolism
Predictive Value of Tests
Prospective Studies
Risk Factors
Stroke
Elsevier B.V.
Metadata display
Abstract
Background and purpose: We analyzed consecutive patients with embolic stroke of undetermined source (ESUS) from three prospective stroke registries to compare the prognostic performance of different LAD thresholds for the prediction of new incident AF. Methods: We calculated the sensitivity, specificity, positive prognostic value (PPV), negative prognostic value (NPV) and Youden's J-statistic of different LAD thresholds to predict new incident AF. We performed multivariate stepwise regression with forward selection of covariates to assess the association between the LAD threshold with the highest Youden's J-statistic and AF detection. Results: Among 675 patients followed for 2437 patient-years, the mean LAD was 38.5 ± 6.8 mm. New incident AF was diagnosed in 115 (17.0%) patients. The LAD threshold of 40mm yielded the highest Youden's J-statistic of 0.35 with sensitivity 0.69, specificity 0.66, PPV 0.27 and NPV 0.92. The likelihood of new incident AF was nearly twice in patients with LAD > 40 mm compared to LAD ≤ 40 mm (HR:1.92, 95%CI:1.24–2.97, p = 0.004). The 10-year cumulative probability of new incident AF was higher in patients with LAD>40 mm compared to LAD ≤ 40 mm (53.5% and 22.4% respectively, log-rank-test: 28.2, p < 0.001). The annualized rate of stroke recurrence of 4.0% in the overall population did not differ significantly in patient above vs. below this LAD threshold (HR:0.96, 95%CI:0.62–1.48, p = 0.85). Conclusions: The LAD threshold of 40 mm has the best prognostic performance among other LAD values to predict new incident AF after ESUS. The diagnostic yield of prolonged cardiac rhythm monitoring in patients with LAD ≤ 40 mm seems low; therefore, such patients may have lower priority for prolonged cardiac monitoring. © 2020 European Federation of Internal Medicine
URI
http://hdl.handle.net/11615/78079
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]

Related items

Showing items related by title, author, creator and subject.

  • Thumbnail

    Embolic Stroke of Undetermined Source and Detection of Atrial Fibrillation on Follow-Up: How Much Causality Is There? 

    Ntaios G., Papavasileiou V., Lip G.Y.H., Milionis H., Makaritsis K., Vemmou A., Koroboki E., Manios E., Spengos K., Michel P., Vemmos K. (2016)
    Background There is increasing debate whether atrial fibrillation (AF) episodes during follow-up in patients with embolic stroke of undetermined source (ESUS) are causally associated with the event. AF-related strokes are ...
  • Thumbnail

    Supraventricular Extrasystoles on Standard 12-lead Electrocardiogram Predict New Incident Atrial Fibrillation after Embolic Stroke of Undetermined Source: The AF-ESUS Study 

    Ntaios G., Perlepe K., Lambrou D., Sirimarco G., Strambo D., Eskandari A., Karagkiozi E., Vemmou A., Koroboki E., Manios E., Makaritsis K., Michel P., Vemmos K. (2020)
    Background: The diagnosis of covert atrial fibrillation (AF) remains a major challenge to guide secondary prevention of patients with embolic stroke of undetermined source (ESUS). Aims: We analyzed consecutive ESUS patients ...
  • Thumbnail

    Identification of patients with embolic stroke of undetermined source and low risk of new incident atrial fibrillation: The AF-ESUS score 

    Ntaios G., Perlepe K., Lambrou D., Sirimarco G., Strambo D., Eskandari A., Karagkiozi E., Vemmou A., Korompoki E., Manios E., Makaritsis K., Vemmos K., Michel P. (2021)
    Background and aims: Only a minority of patients with Embolic Stroke of Undetermined Source (ESUS) receive prolonged cardiac monitoring despite current recommendations. The identification of ESUS patients who have low ...
htmlmap 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister (MyDspace)
Help Contact
DepositionAboutHelpContact Us
Choose LanguageAll of DSpace
EnglishΕλληνικά
htmlmap