On-line SPE sample treatment as a tool for method automatization and detection limits reduction: Quantification of 25-hydroxyvitamin D3/D2

Thumbnail
Autor
Palaiogiannis D., Bekou E., Pazaitou-Panayiotou K., Samanidou V., Tsakalof A.
Datum
2017
Language
en
DOI
10.1016/j.jchromb.2016.10.006
Schlagwort
Biochemistry
Biomolecules
Metabolites
Phase separation
Instrumental analysis
Large volume injection
Large-volume sample injection
Method detection limits
On-line preconcentration
On-line sample preconcentration
On-line solid phase extraction
Vitamin-D
Vitamins
25 hydroxyergocalciferol
calcifediol
drug metabolite
25 hydroxyergocalciferol
calcifediol
Article
assay
automation
controlled study
human
injection
limit of detection
plasma
priority journal
protein binding
serum
solid phase extraction
switching valve
ultra performance liquid chromatography
blood
chemistry
high performance liquid chromatography
isolation and purification
limit of detection
procedures
reproducibility
solid phase extraction
statistical model
25-Hydroxyvitamin D 2
Calcifediol
Chromatography, High Pressure Liquid
Humans
Limit of Detection
Linear Models
Reproducibility of Results
Solid Phase Extraction
Elsevier B.V.
Zur Langanzeige
Zusammenfassung
The development and approbation of new, automated UHPLC-DAD method for the quantification of 25-hydroxyvitamin D3/D2 (25OH-D3/D2) metabolites in plasma/serum for the evaluation of patient's vitamin D status are presented. The method was developed on the Ultimate 3000 UHPLC dual gradient system supplied with the on-line SPE-concentration column coupled through six port switching valve to analytical column. This configuration and materials selected enable large volume sample injection (500 μL) and on-line sample preconcentration, clean up and subsequent selective metabolites transfer onto the analytical column. The new method abrogates main conventional time consuming and error source off-line steps of analysis and thus simplifies analysis. The large volume injection increases the sensitivity of instrumental analysis by about ten-fold on-line pre-concentration of metabolites. The instrument response is linear (R > 0.99) in the investigated concentration range 10–100 ng mL−1 which covers all the possible vitamin D status from serious deficiency (<12 ng mL−1) to excess. The method detection limits (S/N = 3) are LOD (25OH-D3) = 0.94 ng mL−1 and LOD (25OH-D2) = 2.4 ng mL−1. The method performance was assessed with the use of certified reference samples and perfect agreement between certified and measured values is demonstrated. The method was applied to human samples previously analyzed for total vitamin D by Competitive Protein-binding assay and findings of the two methods are compared. © 2016 Elsevier B.V.
URI
http://hdl.handle.net/11615/77432
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]

Verwandte Dokumente

Anzeige der Dokumente mit ähnlichem Titel, Autor, Urheber und Thema.

  • Thumbnail

    Development and validation of a reversed-phase HPLC method for licarbazepine monitoring in serum of patients under oxcarbazepine treatment 

    Begas E., Tsakalof A., Dardiotis E., Vatidis G.E., Kouvaras E., Asprodini E.K. (2017)
    Licarbazepine is the pharmacologically active metabolite of oxcarbazepine, a drug indicated for the treatment of partial seizures and bipolar disorders. Several HPLC methods have been developed thus far but there is lack ...
  • Thumbnail

    Organochlorine pesticide levels in Greek patients with Parkinson's disease 

    Dardiotis E., Aloizou A.-M., Sakalakis E., Siokas V., Koureas M., Xiromerisiou G., Petinaki E., Wilks M., Tsatsakis A., Hadjichristodoulou C., Stefanis L., Hadjigeorgiou G.M. (2020)
    Background: Parkinson's disease (PD) is a neurodegenerative disease, mostly presenting with characteristic motor symptoms. Organochlorines (OC) are a class of widely-used pesticides that have been included among the list ...
  • Thumbnail

    Bootstrap-based testing approaches for the assessment of the diagnostic accuracy of biomarkers subject to a limit of detection 

    Franco-Pereira A.M., Nakas C.T., Leichtle A.B., Pardo M.C. (2019)
    Assessment of the diagnostic accuracy of biomarkers through receiver operating characteristic curve analysis frequently involves a limit of detection imposed by the laboratory analytical system precision. As a consequence, ...
htmlmap 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

EinloggenRegistrieren
Help Contact
DepositionAboutHelpKontakt
Choose LanguageGesamter Bestand
EnglishΕλληνικά
htmlmap