Aldehyde levels in e-cigarette aerosol: Findings from a replication study and from use of a new-generation device

Thumbnail
Auteur
Farsalinos K.E., Kistler K.A., Pennington A., Spyrou A., Kouretas D., Gillman G.
Date
2018
Language
en
DOI
10.1016/j.fct.2017.11.002
Sujet
acetaldehyde
acrolein
aldehyde
formaldehyde
aldehyde
nicotine
aerosol
Article
CE4v2 atomizer
chemical analysis
controlled study
electric potential
high performance liquid chromatography
Nautilus Mini atomizer
replication study
smoking
aerosol
chemistry
electronic cigarette
human
vaping
Aerosols
Aldehydes
Electronic Nicotine Delivery Systems
Humans
Nicotine
Vaping
Elsevier Ltd
Afficher la notice complète
Résumé
Purpose A recent study identified high aldehyde emissions from e-cigarettes (ECs), that when converted to reasonable daily human EC liquid consumption, 5 g/day, gave formaldehyde exposure equivalent to 604–3257 tobacco cigarettes. We replicated this study and also tested a new-generation atomizer under verified realistic (no dry puff) conditions. Design CE4v2 atomizers were tested at 3.8 V and 4.8 V, and a Nautilus Mini atomizer was tested at 9.0 W and 13.5 W. All measurements were performed in a laboratory ISO-accredited for EC aerosol collection and aldehyde measurements. Results CE4v2 generated dry puffs at both voltage settings. Formaldehyde levels were >10-fold lower, acetaldehyde 6–9-fold lower and acrolein 16–26-fold lower than reported in the previous study. Nautilus Mini did not generate dry puffs, and minimal aldehydes were emitted despite >100% higher aerosol production per puff compared to CE4v2 (formaldehyde: 16.7 and 16.5 μg/g; acetaldehyde: 9.6 and 10.3 μg/g; acrolein: 8.6 and 11.7 μg/g at 9.0 W and 13.5 W, respectively). EC liquid consumption of 5 g/day reduces aldehyde exposure by 94.4–99.8% compared to smoking 20 tobacco cigarettes. Conclusion Checking for dry puffs is essential for EC emission testing. Under realistic conditions, new-generation ECs emit minimal aldehydes/g liquid at both low and high power. Validated methods should be used when analyzing EC aerosol. © 2017 Elsevier Ltd
URI
http://hdl.handle.net/11615/71478
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]