Optimization of thermal performance of a building with ground source heat pump system

Thumbnail
Author
Zogou, O.; Stamatelos, A.
Date
2007
DOI
10.1016/j.enconman.2007.07.012
Keyword
heat pumps
building energy simulation
optimization
HVAC systems
design
ENERGY ANALYSIS
STORAGE
DESIGN
HOUSE
Thermodynamics
Energy & Fuels
Mechanics
Physics, Nuclear
Metadata display
Abstract
Component optimization studies during the last twenty years, point to the use of carefully optimized ground source heat pump systems as a means of reducing building heating and cooling energy costs. Modern computational tools enable building energy simulation with a time step of the order of minutes. This allows improved insight in the building HVAC system's transient operation and may affect the form of the objective functions employed in the component optimization procedure. In this paper, the yearly performance of a 3-zone residential building located in Volos, Greece, equipped with a conventional chiller boiler system, compared to that of an alternative, ground source heat pump system, are simulated in the TRNSYS 16 environment. Comparative year-round simulations are employed to demonstrate the expected transient and overall energy balance effects of control settings, chiller or heat pump COP characteristics, equipment sizing and other design parameters. It is concluded that detailed simulation of the HVAC system operation further improves our understanding of its transient operation. Furthermore, it allows more realistic system's sizing, better assessment of the effect of control settings, chiller or heat pump COP characteristics and other design parameters. (C) 2007 Elsevier Ltd. All rights reserved.
URI
http://hdl.handle.net/11615/35009
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister (MyDspace)
Help Contact
DepositionAboutHelpContact Us
Choose LanguageAll of DSpace
EnglishΕλληνικά
htmlmap