Patient-specific internal radionuclide dosimetry

Thumbnail
Auteur
Tsougos, I.; Loudos, G.; Georgoulias, P.; Theodorou, K.; Kappas, C.
Date
2010
DOI
10.1097/MNM.0b013e328330626f
Sujet
absorbed dose
dosimetry
Monte Carlo
nuclear medicine
radionuclide
therapy
tomographic data
treatment planning
PERSONAL-COMPUTER SOFTWARE
ABSORBED FRACTIONS
3-DIMENSIONAL DOSIMETRY
SIMULATION TOOLKIT
RADIATION-THERAPY
LYMPHOMA PATIENTS
NUCLEAR-MEDICINE
DOSE ASSESSMENT
PET
SPECT
Radiology, Nuclear Medicine & Medical Imaging
Afficher la notice complète
Résumé
The development of patient-specific treatment planning systems is of outmost importance in the development of radionuclide dosimetry, taking into account that quantitative three-dimensional nuclear medical imaging can be used in this regard. At present, the established method for dosimetry is based on the measurement of the biokinetics by serial gamma-camera scans, followed by calculations of the administered activity and the residence times, resulting in the radiation-absorbed doses of critical organs. However, the quantification of the activity in different organs from planar data is hampered by inaccurate attenuation and scatter correction as well as because of background and organ overlay. In contrast, dosimetry based on quantitative three-dimensional data can be more accurate and allows an individualized approach, provided that all effects that degrade the quantitative content of the images have been corrected for. In addition, inhomogeneous organ accumulation of the radionuclide can be detected and possibly taken into account. The aim of this work is to provide adequate information on internal emitter dosimetry and a state-of-the-art review of the current methodology and future trends. Nucl Med Commun 31:97-106 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
URI
http://hdl.handle.net/11615/34064
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une sessionS'inscrire
Help Contact
DepositionAboutHelpContactez-nous
Choose LanguageTout DSpace
EnglishΕλληνικά
htmlmap