Εμφάνιση απλής εγγραφής

dc.creatorVaios V., Georgianos P.I., Pikilidou M.I., Eleftheriadis T., Zarogiannis S., Papagianni A., Zebekakis P.E., Liakopoulos V.en
dc.date.accessioned2023-01-31T10:24:10Z
dc.date.available2023-01-31T10:24:10Z
dc.date.issued2018
dc.identifier.issn11978554
dc.identifier.urihttp://hdl.handle.net/11615/80330
dc.description.abstractThe aim of the present study was to compare the aortic systolic blood pressure (aSBP), heart-rate-adjusted augmentation index (AIx75), and pulse wave velocity (PWV) obtained using the Mobil-O-Graph (IEM, Stolberg, Germany) and SphygmoCor (AtCor, Sydney, Australia) devices in patients receiving peritoneal dialysis (PD).After a 10-minute rest in the supine position, the Mobil-O-Graph and SphygmoCor devices were applied in randomized order in 27 consecutive PD patients. The agreement between the measurements produced by the Mobil-O-Graph and SphygmoCor devices was explored using Bland-Altman analysis.The Mobil-O-Graph-derived aSBP, AIx75, and PWV did not differ from the same measurements obtained with SphygmoCor (aSBP: 120.5 ± 18.2 mmHg vs. 124.4 ± 19.0 mmHg, p = 0.438; AIx75: 27.0% ± 12.4% vs. 24.5% ± 10.6%, p = 0.428; PWV: 9.5 ± 2.1 m/s vs. 10.1 ± 3.1 m/s, p = 0.397). The slight difference in the estimation of aSBP is possibly explained by the difference in brachial SBP used for the calibration of the devices (131.0 ± 20.6 mmHg vs. 134.5 ± 19.7 mmHg, p = 0.525). Mobil-O-Graph-derived measurements correlated strongly with paired measurements obtained with the SphygmoCor device. Bland-Altman plots showed no evidence of asymmetry and a wide range of agreement between the two devices.Our study shows acceptable agreement between Mobil-O-Graph and SphygmoCor in the estimation of arterial stiffness indices in PD patients. Accordingly, the Mobil-O-Graph device accurately performs aortic ambulatory blood pressure monitoring in this population.en
dc.language.isoenen
dc.sourceAdvances in peritoneal dialysis. Conference on Peritoneal Dialysisen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85057209371&partnerID=40&md5=25d0a8f02022ac1eaca5c8ba9cce5772
dc.subjectarterial stiffnessen
dc.subjectblood pressureen
dc.subjectblood pressure monitoringen
dc.subjecthumanen
dc.subjectoscillometryen
dc.subjectperitoneal dialysisen
dc.subjectpulse waveen
dc.subjectvalidation studyen
dc.subjectBlood Pressureen
dc.subjectBlood Pressure Monitoring, Ambulatoryen
dc.subjectHumansen
dc.subjectOscillometryen
dc.subjectPeritoneal Dialysisen
dc.subjectPulse Wave Analysisen
dc.subjectVascular Stiffnessen
dc.subjectNLM (Medline)en
dc.titleAccuracy of a Newly-Introduced Oscillometric Device for the Estimation of Arterial Stiffness Indices in Patients on Peritoneal Dialysis: A Preliminary Validation Studyen
dc.typejournalArticleen