Analysis of the impact of automatic shading control scenarios on occupant's comfort and energy load

Thumbnail
Autor
Tabadkani A., Roetzel A., Xian Li H., Tsangrassoulis A., Attia S.
Datum
2021
Language
en
DOI
10.1016/j.apenergy.2021.116904
Schlagwort
Adaptive control systems
Energy management
Simulation platform
Solar radiation
Adaptive facade
Building envelopes
Building performance simulations
Condition
Energy
Management systems
Occupant comforts
Shading control
User comforts
User interaction
Energy management systems
basement (building)
boundary condition
building
detection method
environmental conditions
indoor air
sensory system
simulation
solar radiation
Elsevier Ltd
Zur Langanzeige
Zusammenfassung
Building envelopes should be responsive to boundary conditions changing in short-time, daily, or seasonal patterns. To this end, adaptive facades provide the ability to react, or benefit from, outdoor fluctuations and dynamic indoor requirements. On the other hand, the parallel trend of developing new technologies to control their performance, make adaptive facades more applicable to counterbalance both user's comfort and building energy load. This goal can be met using active control mechanisms, either manually or automatically. Automatic shading controls require indoor/outdoor signal inputs to operate a shading system. However, in the literature, there is no consent on the effectiveness of automatic shading control strategies and all of the studies were investigated within specific environmental conditions. Therefore, this paper aims to compare the most used control functions and their implications on user comfort and energy load in different climate zones. To this end, EnergyPlus was used as a simulation platform to employ Energy Management System (EMS) for linking sensors, actuators to the control logic of adaptive venetian blinds. Then, a brute-force method was performed through Ladybug-tools to conduct 15,390 iterations parametrically. Results showed that climatic conditions impact the shading control scenario significantly, and the optimum scenario was an open-loop algorithm based on direct solar radiation due to the earlier activation of blind closure to block solar radiation while increasing lighting load at the same time. © 2021 Elsevier Ltd
URI
http://hdl.handle.net/11615/79572
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

EinloggenRegistrieren
Help Contact
DepositionAboutHelpKontakt
Choose LanguageGesamter Bestand
EnglishΕλληνικά
htmlmap