dc.description.abstractOBJECTIVES The objective of this study is to analyse the flow conditions in the AFX and Nellix endografts (EGs) accounting for their postimplantation configuration in patients with an endovascular aneurysm repair-treated abdominal aortic aneurysm. METHODS We reconstructed post-endovascular aneurysm repair computed tomography scans of patients treated with an AFX or Nellix EG creating post-implantation EG models. We examined 16 patients, 8 in each group. The blood flow properties were obtained by computational fluid dynamics simulations and were subsequently compared with physiological infrarenal blood flow properties measured in 5 healthy subjects. Specifically, pressure drop, maximum velocity and wall shear stress were measured at peak systole and mean helicity at mid-diastole. RESULTS Our statistical analyses showed that the haemodynamic properties in both control regions did not vary statistically after the implantation of either the AFX or the Nellix EG, except for helicity that was significantly lower in the abdominal part of the Nellix EG compared with the expected physiological measurement. Regardless of the overall blood flow restoration, it is important to note that low pressure drop was detected along the limbs of the AFX and suppressed blood helical motion was detected at the entrance of the Nellix device. CONCLUSIONS It is observed from the results that the AFX EG has achieved absolute restoration of blood flow after endovascular aneurysm repair, although the development of secondary flow in the upper part of the EG and the low pressure drop in its limbs should be acknowledged. The Nellix EG also seems to be haemodynamically efficient. However, the suppression of helical flow before blood enters the device might raise concerns about its clinical application. © 2018 The Author.en
dc.language.isoenen
dc.sourceInteractive Cardiovascular and Thoracic Surgeryen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85047222720&doi=10.1093%2ficvts%2fivx414&partnerID=40&md5=a41fd9168866dd629911c30ddf7cb2be
dc.subjectabdominal aortic aneurysmen
dc.subjectArticleen
dc.subjectblood flowen
dc.subjectblood flow velocityen
dc.subjectblood vessel parametersen
dc.subjectclinical articleen
dc.subjectcomputational fluid dynamicsen
dc.subjectcomputer assisted tomographyen
dc.subjectcontrolled studyen
dc.subjectdiastoleen
dc.subjectendovascular aneurysm repairen
dc.subjectheart cycleen
dc.subjecthemodynamicsen
dc.subjecthumanen
dc.subjectimage reconstructionen
dc.subjectimplantationen
dc.subjectpeak systolic velocityen
dc.subjectpressure dropen
dc.subjectpriority journalen
dc.subjectshear stressen
dc.subjectsimulationen
dc.subjectabdominal aortic aneurysmen
dc.subjectageden
dc.subjectblood vessel prosthesisen
dc.subjectblood vessel transplantationen
dc.subjectdevicesen
dc.subjectendovascular surgeryen
dc.subjectfemaleen
dc.subjecthemodynamicsen
dc.subjecthydrodynamicsen
dc.subjectmaleen
dc.subjectmechanical stressen
dc.subjectpathophysiologyen
dc.subjectphysiologyen
dc.subjectpressureen
dc.subjectproceduresen
dc.subjectprosthesis designen
dc.subjectstenten
dc.subjecttreatment outcomeen
dc.subjectx-ray computed tomographyen
dc.subjectAgeden
dc.subjectAortic Aneurysm, Abdominalen
dc.subjectBlood Vessel Prosthesisen
dc.subjectBlood Vessel Prosthesis Implantationen
dc.subjectEndovascular Proceduresen
dc.subjectFemaleen
dc.subjectHemodynamicsen
dc.subjectHumansen
dc.subjectHydrodynamicsen
dc.subjectMaleen
dc.subjectPressureen
dc.subjectProsthesis Designen
dc.subjectStentsen
dc.subjectStress, Mechanicalen
dc.subjectTomography, X-Ray Computeden
dc.subjectTreatment Outcomeen
dc.subjectOxford University Pressen
dc.titleHaemodynamic performance of AFX and Nellix endografts: A computational fluid dynamics studyen
dc.typejournalArticleen