dc.description.abstractPurpose: The Genesis II Total Knee Arthroplasty with an oxidized zirconium (OxiniumTM) femoral component (Smith & Nephew, Memphis, TN, USA) was introduced in an attempt to reduce polyethylene wear and osteolysis. Methods: We retrospectively evaluated prospectively collected data from 245 consecutive patients (40 men and 205 women; mean age at surgery 70.1 years, range 44 to 85 years) who underwent 261 TKAs with a mean follow-up of 15.1 years (range 13 to 16 years). Implant failure rate, complication rate, clinical (both subjective and objective) and radiological outcomes were assessed. Results: At final follow-up, 24 (9.8 %) patients (24 TKAs) were lost to follow-up and 35 (14.3%) patients (35 TKAs) had died for reasons unrelated to surgery. Four TKAs, in four patients, were revised because of aseptic loosening. In five TKAs (five patients) secondary patella resurfacing was performed because of patellofemoral pain. Survivorship analysis showed a cumulative success rate of 98.4% (95% CI, 94.3% - 100%) at 15 years with revision for aseptic loosening as an end point, and 95.6% (95% CI, 92.7% - 98.7%) at 15 years with revision for any reason as an end point. All patients showed a statistically significant improvement (p = 0.01) in the Knee Society clinical rating system, WOMAC Score, KOOS Score, Oxford Knee Score and EuroQol 5D Score. Surgery fulfilled patient expectations for 90.1% of patients; in 5.4% it did not, and 4.5% declined to answer. Conclusion: This study demonstrates satisfactory long-term clinical results for this knee design. © 2019 Elsevier B.V.en
dc.language.isoenen
dc.sourceKneeen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85061452344&doi=10.1016%2fj.knee.2019.01.013&partnerID=40&md5=34b4eeb7dc96e8f2742b84ae87ff7e8d
dc.subjectzirconiumen
dc.subjectbiomaterialen
dc.subjectzirconiumen
dc.subjectzirconium oxideen
dc.subjectadulten
dc.subjectageden
dc.subjectArticleen
dc.subjectclinical studyen
dc.subjectEuroQol 5D Scoreen
dc.subjectfemaleen
dc.subjectfollow upen
dc.subjecthumanen
dc.subjectKOOS Scoreen
dc.subjectmajor clinical studyen
dc.subjectmaleen
dc.subjectoutcome assessmenten
dc.subjectOxford Kneeen
dc.subjectpatellofemoral pain syndromeen
dc.subjectpatient satisfactionen
dc.subjectpriority journalen
dc.subjectprospective studyen
dc.subjectprosthesis looseningen
dc.subjectretrospective studyen
dc.subjectscoring systemen
dc.subjectsurvivorshipen
dc.subjecttotal knee arthroplastyen
dc.subjecttreatment failureen
dc.subjectWOMAC Scoreen
dc.subjectadverse device effecten
dc.subjectdevicesen
dc.subjectetiologyen
dc.subjectfemuren
dc.subjectkneeen
dc.subjectknee prosthesisen
dc.subjectknee replacementen
dc.subjectmiddle ageden
dc.subjectosteolysisen
dc.subjectproceduresen
dc.subjectprosthesis complicationen
dc.subjectprosthesis designen
dc.subjectsurgeryen
dc.subjecttreatment outcomeen
dc.subjectvery elderlyen
dc.subjectAdulten
dc.subjectAgeden
dc.subjectAged, 80 and overen
dc.subjectArthroplasty, Replacement, Kneeen
dc.subjectBiocompatible Materialsen
dc.subjectFemaleen
dc.subjectFemuren
dc.subjectFollow-Up Studiesen
dc.subjectHumansen
dc.subjectKnee Jointen
dc.subjectKnee Prosthesisen
dc.subjectMaleen
dc.subjectMiddle Ageden
dc.subjectOsteolysisen
dc.subjectProsthesis Designen
dc.subjectProsthesis Failureen
dc.subjectRetrospective Studiesen
dc.subjectTreatment Outcomeen
dc.subjectZirconiumen
dc.subjectElsevier B.V.en
dc.titleA 13- to 16-year clinical and radiological outcome study of the genesis II cruciate retaining total knee arthroplasty with an oxidised zirconium femoral componenten