Εμφάνιση απλής εγγραφής

dc.creatorOikonomidou R., Petridis D., Kosmidis C., Sapalidis K., Hohenforst-Schmidt W., Christakidis V., Petanidis S., Mathaios D., Perdikouri E.I., Baka S., Tolis C., Vagionas A., Zaric B., Ioannidis A., Anemoulis M., Porpodis K., Papadopoulos V., Zarogoulidis P.en
dc.date.accessioned2023-01-31T09:41:01Z
dc.date.available2023-01-31T09:41:01Z
dc.date.issued2022
dc.identifier10.7150/jca.75589
dc.identifier.issn18379664
dc.identifier.urihttp://hdl.handle.net/11615/77374
dc.description.abstractIntroduction: We have been using cryo-biopsy for endobronchial lesions for lung cancer diagnosis and debulking. Cryo-biopsy is also known to be an excellent tool for diagnosis of lung interstitial disease. Recently cryo-biopsy with the 1.1mm probe was used for lymphnode biopsy. Patients and Methods: 311 patients participated with lymphadenopathy and at least one lung lesion. The following tools were used for diagnosis; 22G Mediglobe Sonotip, 22G Medigolbe, 21G Olympus, 19G Olympus and 1.1mm cryo probe ERBE CRYO 2 system (3 seconds froze). A PENTAX Convex-probe EBUS was used for biopsy guidance. Results: Cell-blocks slices had a higher number in the 19G needle group (19G> Cryo Probe>22G Mediglobe Sonotip >21G Olympus >22G Mediglobe). Conclusion: Cryo biopsy of the lymphnodes is safe with the 1.1mm cryo probe. Further studies are needed in order to evaluate new probes and the technique specifications. © The author(s).en
dc.language.isoenen
dc.sourceJournal of Canceren
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85136166341&doi=10.7150%2fjca.75589&partnerID=40&md5=264d2854d18d0573c630eba147265fc7
dc.subjectadulten
dc.subjectadverse eventen
dc.subjectageden
dc.subjectArticleen
dc.subjectbleedingen
dc.subjectcancer diagnosisen
dc.subjectcomparative studyen
dc.subjectcontrolled studyen
dc.subjectcryobiopsyen
dc.subjectendobronchial ultrasonographyen
dc.subjectendoscopyen
dc.subjectfemaleen
dc.subjecthumanen
dc.subjecthuman tissueen
dc.subjectlung canceren
dc.subjectlung lesionen
dc.subjectlymph node biopsyen
dc.subjectlymphadenopathyen
dc.subjectmajor clinical studyen
dc.subjectmaleen
dc.subjectneedle biopsyen
dc.subjectIvyspring International Publisheren
dc.titleCryo-Biopsy versus 19G needle versus 22G needle with EBUS-TBNA endoscopyen
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής