Mostrar el registro sencillo del ítem
Effectiveness of different confining configurations of FRP jackets for concrete columns
dc.creator | Moretti M.L. | en |
dc.date.accessioned | 2023-01-31T09:01:09Z | |
dc.date.available | 2023-01-31T09:01:09Z | |
dc.date.issued | 2019 | |
dc.identifier | 10.12989/sem.2019.72.2.155 | |
dc.identifier.issn | 12254568 | |
dc.identifier.uri | http://hdl.handle.net/11615/76733 | |
dc.description.abstract | This paper presents the results of an experimental investigation on the compressive strength of small scale concentrically axially loaded fiber-reinforced polymer (FRP) confined plain concrete columns, with cylinder concrete strength 19 MPa. For columns with circular (150-mm diameter) and square (150-mm side) cross sections wrapped with glass- and carbon- FRP sheets (GFRP and CFRP, respectively) applied with dry lay-up the effect of different jacket schemes and different overlap configurations on the confined characteristics is investigated. Test results indicate that the most cost effective jacket configuration among those tested is for one layer of CFRP, for both types of sections. In square sections the location of the lap length, either in the corner or along the side, does not seem to affect the confined performance. Furthermore, in circular sections, the presence of an extra wrap with FRP fibers parallel to the column’s axis enhances the concrete strength proportionally to the axial rigidity of the FRP jacket. The recorded strains and the distributions of lateral confining pressures are discussed. Existing design equations are used to assess the lateral confining stresses and the confined concrete strength making use of the measured hoop strains. Copyright © 2019 Techno-Press, Ltd. | en |
dc.language.iso | en | en |
dc.source | Structural Engineering and Mechanics | en |
dc.source.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85074422714&doi=10.12989%2fsem.2019.72.2.155&partnerID=40&md5=2a9dfd32c2e05995a45a26eafb6e42dd | |
dc.subject | Columns (structural) | en |
dc.subject | Compressive strength | en |
dc.subject | Concrete construction | en |
dc.subject | Concretes | en |
dc.subject | Cost effectiveness | en |
dc.subject | Cylinders (shapes) | en |
dc.subject | Elasticity | en |
dc.subject | Fiber reinforced materials | en |
dc.subject | Fiber reinforced plastics | en |
dc.subject | Fibers | en |
dc.subject | Reinforcement | en |
dc.subject | Concrete strength | en |
dc.subject | Confined concrete | en |
dc.subject | Confining stress | en |
dc.subject | Cubes | en |
dc.subject | Experimental investigations | en |
dc.subject | Fiber reinforced polymers | en |
dc.subject | Lateral confining pressure | en |
dc.subject | Overlap | en |
dc.subject | Fiber reinforced concrete | en |
dc.subject | Techno-Press | en |
dc.title | Effectiveness of different confining configurations of FRP jackets for concrete columns | en |
dc.type | journalArticle | en |
Ficheros en el ítem
Ficheros | Tamaño | Formato | Ver |
---|---|---|---|
No hay ficheros asociados a este ítem. |