dc.description.abstractPurpose: The aim of the study was to systematically evaluate clinical outcomes of tapered fluted stems, either monoblock or modular, in revision total hip arthroplasty. Methods: PubMed, EMBASE and Web of Science and Cochrane databases were systematically searched by 2 researchers. Clinical studies reporting primarily on survival and re-revision rates, and secondarily on subsidence, dislocation, intraoperative fractures, periprosthetic fractures and infection were included. 2 investigators assessed the quality of the studies. Results: 46 studies were included in this review, reporting on 4601 stem revisions. The pooled re-revision rate was 5.1% and long-term survival ranged from 75% to 98.5%. No differences were observed between monoblock and modular stems regarding re-revision rate, dislocation rate, periprosthetic fracture rate or infection rates. Monoblock stems exhibited more subsidence and modular stems displayed more intraoperative fractures. Conclusions: Satisfactory results can be obtained with the use of tapered fluted end-bearing stems. Monoblock stems offer the same clinical results as modular stems. © The Author(s) 2021.en
dc.language.isoenen
dc.sourceHIP Internationalen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85104233630&doi=10.1177%2f11207000211004383&partnerID=40&md5=dccbecc6a60165769ff8ee4c9852209f
dc.subjectArticleen
dc.subjectdislocationen
dc.subjectfollow upen
dc.subjecthip arthroplastyen
dc.subjecthip replacementen
dc.subjecthumanen
dc.subjectinfectionen
dc.subjectinfection rateen
dc.subjectlong term survivalen
dc.subjectmeta analysisen
dc.subjectperiprosthetic fractureen
dc.subjectradiographyen
dc.subjectremissionen
dc.subjectsystematic reviewen
dc.subjecttendon graften
dc.subjecttotal hip replacementen
dc.subjectadverse eventen
dc.subjectdiagnostic imagingen
dc.subjectfemuren
dc.subjecthip prosthesisen
dc.subjecthip replacementen
dc.subjectjoint dislocationen
dc.subjectperiprosthetic fractureen
dc.subjectprosthesis designen
dc.subjectreoperationen
dc.subjectretrospective studyen
dc.subjecttitaniumen
dc.subjectArthroplasty, Replacement, Hipen
dc.subjectFemuren
dc.subjectHip Prosthesisen
dc.subjectHumansen
dc.subjectJoint Dislocationsen
dc.subjectPeriprosthetic Fracturesen
dc.subjectProsthesis Designen
dc.subjectReoperationen
dc.subjectRetrospective Studiesen
dc.subjectTitaniumen
dc.subjectSAGE Publications Ltden
dc.titleClinical, functional and radiographic outcomes after revision total hip arthroplasty with tapered fluted modular or non-modular stems: a systematic reviewen
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής