dc.description.abstract | Background: The cemented Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary knee kinematics data and has shown satisfactory long-term outcomes. Methods: We retrospectively evaluated prospectively collected data from 2 groups of patients. Group A consisted of 54 patients (54 TKAs), 18 men and 36 women, and mean age at surgery was 63.2 ± 5.2 years; group B consisted of 54 patients (54 TKAs), 17 men and 37 women, and mean age at surgery was 63.8 ± 5.1 years. Patients of both groups were matched for age, gender, side, body mass index, and length of follow-up. The cementless components of this design were implanted in group A and the cemented in group B. Implant failure, complication rates, clinical (both subjective and objective) and radiological outcomes were assessed in all patients of both groups. Results: All patients of both groups were available for final follow-up evaluation at a mean of 8.6 ± 0.4 years. Survival analysis at 9 years showed a cumulative success rate of 100% in both groups with all end points. In neither group were implant-related, surgeon-related, or patient-related failures observed. When both groups were compared, in all time intervals, no differences were recorded on Knee Society system, Western Ontario and McMaster University Osteoarthritis Index, Short Form-12, and Oxford Knee Scores. On radiological examination, for both groups, all parameters evaluated were satisfactory. Conclusion: This study presents satisfactory midterm clinical and radiological outcomes with the use of both versions of this design. Moreover, no implant-related failures were observed with the use of cancellous titanium-coated tibial implants. © 2018 The Authors | en |
dc.language.iso | en | en |
dc.source | Journal of Arthroplasty | en |
dc.source.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85050807718&doi=10.1016%2fj.arth.2018.07.014&partnerID=40&md5=17d50591f87ab1180f2abc115a9c3b81 | |
dc.subject | adult | en |
dc.subject | aged | en |
dc.subject | Article | en |
dc.subject | body mass | en |
dc.subject | clinical outcome | en |
dc.subject | controlled study | en |
dc.subject | deep vein thrombosis | en |
dc.subject | echography | en |
dc.subject | female | en |
dc.subject | follow up | en |
dc.subject | human | en |
dc.subject | knee function | en |
dc.subject | knee osteoarthritis | en |
dc.subject | knee pain | en |
dc.subject | knee radiography | en |
dc.subject | Knee Society Score | en |
dc.subject | major clinical study | en |
dc.subject | male | en |
dc.subject | Oxford Knee Score | en |
dc.subject | postoperative period | en |
dc.subject | preoperative evaluation | en |
dc.subject | retrospective study | en |
dc.subject | Short Form 12 | en |
dc.subject | skin necrosis | en |
dc.subject | survival analysis | en |
dc.subject | total knee arthroplasty | en |
dc.subject | Western Ontario and McMaster Universities Osteoarthritis Index | en |
dc.subject | comparative study | en |
dc.subject | devices | en |
dc.subject | diagnostic imaging | en |
dc.subject | knee | en |
dc.subject | knee prosthesis | en |
dc.subject | knee replacement | en |
dc.subject | middle aged | en |
dc.subject | radiography | en |
dc.subject | statistics and numerical data | en |
dc.subject | tibia | en |
dc.subject | treatment outcome | en |
dc.subject | bone cement | en |
dc.subject | titanium | en |
dc.subject | Aged | en |
dc.subject | Arthroplasty, Replacement, Knee | en |
dc.subject | Bone Cements | en |
dc.subject | Female | en |
dc.subject | Humans | en |
dc.subject | Knee Joint | en |
dc.subject | Knee Prosthesis | en |
dc.subject | Male | en |
dc.subject | Middle Aged | en |
dc.subject | Osteoarthritis, Knee | en |
dc.subject | Radiography | en |
dc.subject | Retrospective Studies | en |
dc.subject | Tibia | en |
dc.subject | Titanium | en |
dc.subject | Treatment Outcome | en |
dc.subject | Churchill Livingstone Inc. | en |
dc.title | A 9-Year Outcome Study Comparing Cancellous Titanium-Coated Cementless to Cemented Tibial Components of a Single Knee Arthroplasty Design | en |
dc.type | journalArticle | en |
Ficheros en el ítem
Ficheros | Tamaño | Formato | Ver |
---|---|---|---|
No hay ficheros asociados a este ítem. |