Εμφάνιση απλής εγγραφής

dc.creatorKaltsatou A., Hadjigeorgiou G.M., Grigoriou S.S., Karatzaferi C., Giannaki C.D., Lavdas E., Fotiou D., Kouidi E., Patramani G., Vogiatzi C., Pappas A., Stefanidis I., Sakkas G.K.en
dc.date.accessioned2023-01-31T08:29:46Z
dc.date.available2023-01-31T08:29:46Z
dc.date.issued2019
dc.identifier10.1080/00325481.2019.1663707
dc.identifier.issn00325481
dc.identifier.urihttp://hdl.handle.net/11615/74227
dc.description.abstractObjectives: Cardiac autonomic nervous system (ANS) dysfunction is a common feature in patients receiving hemodialysis (HD) therapy, whilst is associated with an increased risk of ventricular arrhythmias and sudden cardiac death. The aim of this study is to investigate and compare the hemodynamic changes and responses of ANS function in HD patients using pupillometry and Heart Rate Variability (HRV) parameters. Methods: Sixteen chronic kidney diseases (CKD) patients receiving HD (52.18 ± 17.7 years) underwent both pupillometric measurements using a portable handheld pupil-measuring device and standard HRV analysis pre HD, every hour and 30 min post-HD session under two different scenarios: at rest while the patient resting at HD bed and when the patient performed a single bout of intradialytic aerobic exercise lasting for 45 min during the second hour of the HD therapy. Results: No significant changes in ANS values were observed in neither of the pupillometric and the HRV values pre HD, for each hour and post-HD session. HRV parameters were significantly correlated with pupillometric parameters at pre HD and immediately after the single bout of intradialytic exercise. ANS activity did not differ during the conventional HD session and during the session included intradialytic exercise. Moreover, sympatho-vagal balance indices deriving from pupillometric assessment showed beneficial changes after the exercise event. Conclusion: Pupillometry is a promising and robust technique with fewer artifacts compared to HRV especially in studies involving exercise sessions. Thus, pupillometry can be used as a complementary tool in the evaluation of cardiac autonomic dysfunction. © 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group.en
dc.language.isoenen
dc.sourcePostgraduate Medicineen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85073182986&doi=10.1080%2f00325481.2019.1663707&partnerID=40&md5=b76afa9d9aad12fd254ed7937cc134d9
dc.subjectenoxaparinen
dc.subjecthemoglobinen
dc.subjectadulten
dc.subjectarterial pressureen
dc.subjectarteriovenous fistulaen
dc.subjectArticleen
dc.subjectautonomic dysfunctionen
dc.subjectchronic kidney failureen
dc.subjectclinical articleen
dc.subjectdialysisen
dc.subjectdiastolic blood pressureen
dc.subjectevaluation studyen
dc.subjectexerciseen
dc.subjecteye diseaseen
dc.subjectfemaleen
dc.subjectheart functionen
dc.subjecthumanen
dc.subjectintradialytic exercise trainingen
dc.subjectmaleen
dc.subjectmiddle ageden
dc.subjectpupilen
dc.subjectpupillometryen
dc.subjectresting heart rateen
dc.subjectsystolic blood pressureen
dc.subjectvascular accessen
dc.subjectageden
dc.subjectautonomic nervous systemen
dc.subjectautonomic neuropathyen
dc.subjectchronic kidney failureen
dc.subjectexerciseen
dc.subjectheart rateen
dc.subjecthemodialysisen
dc.subjectpathophysiologyen
dc.subjectphysiologyen
dc.subjectAdulten
dc.subjectAgeden
dc.subjectAutonomic Nervous Systemen
dc.subjectAutonomic Nervous System Diseasesen
dc.subjectExerciseen
dc.subjectHeart Rateen
dc.subjectHumansen
dc.subjectMiddle Ageden
dc.subjectPupilen
dc.subjectRenal Dialysisen
dc.subjectRenal Insufficiency, Chronicen
dc.subjectTaylor and Francis Inc.en
dc.titleCardiac autonomic function during intradialytic exercise trainingen
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής