Zur Kurzanzeige

dc.creatorDragon-Durey M.-A., Bizzaro N., Senant M., Andreeva H., Bogdanos D.P., Bonroy C., Bossuyt X., Eriksson C., Fabien N., Heijnen I., Herold M., Musset L., Kuhi L., Lopez-Hoyos M., Berki T., Roozendaal C., Sack U., Sundic T., Taylor L., Kuna A.T., Damoiseaux J.en
dc.date.accessioned2023-01-31T07:59:19Z
dc.date.available2023-01-31T07:59:19Z
dc.date.issued2022
dc.identifier10.1515/cclm-2022-0411
dc.identifier.issn14346621
dc.identifier.urihttp://hdl.handle.net/11615/73466
dc.description.abstractObjectives: No reference data are available on repositories to measure precision of autoantibody assays. The scope of this study was to document inter- and intra-run variations of quantitative autoantibody assays based on a real-world large international data set. Methods: Members of the European Autoimmunity Standardisation Initiative (EASI) group collected the data of intra- and inter-run variability obtained with assays quantifying 15 different autoantibodies in voluntary participating laboratories from their country. We analyzed the impact on the assay performances of the type of immunoassay, the number of measurements used to calculate the coefficient of variation (CVs), the nature and the autoantibody level of the internal quality control (IQC). Results: Data were obtained from 64 laboratories from 15 European countries between February and October 2021. We analyzed 686 and 1,331 values of intra- and inter-run CVs, respectively. Both CVs were significantly dependent on: the method of immunoassay, the level of IQC with higher imprecision observed when the antibody levels were lower than 2-fold the threshold for positivity, and the nature of the IQC with commercial IQCs having lower CVs than patients-derived IQCs. Our analyses also show that the type of autoantibody has low impact on the assay' performances and that 15 measurements are sufficient to establish reliable intra- and inter-run variations. Conclusions: This study provides for the first time an international repository yielding values of intra- and inter-run variation for quantitative autoantibody assays. These data could be useful for ISO 15189 accreditation requirements and will allow clinical diagnostic laboratories to assure quality of patient results. © 2022 Walter de Gruyter GmbH, Berlin/Boston.en
dc.language.isoenen
dc.sourceClinical Chemistry and Laboratory Medicineen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85133542085&doi=10.1515%2fcclm-2022-0411&partnerID=40&md5=38e1e885d620b9c7245749f487423dcf
dc.subjectautoantibodyen
dc.subjectbeta2 glycoprotein 1 antibodyen
dc.subjectcardiolipin antibodyen
dc.subjectcyclic citrullinated peptide antibodyen
dc.subjectdouble stranded DNA antibodyen
dc.subjectgliadin antibodyen
dc.subjectimmunoglobulin Gen
dc.subjectimmunoglobulin Men
dc.subjectprotein glutamine gamma glutamyltransferase antibodyen
dc.subjectrheumatoid factoren
dc.subjectthyroglobulin antibodyen
dc.subjectthyrotropin receptor antibodyen
dc.subjectautoantibodyen
dc.subjectaccreditationen
dc.subjectaddressable laser bead immunoassayen
dc.subjectArticleen
dc.subjectAustriaen
dc.subjectBelgiumen
dc.subjectbenchmarkingen
dc.subjectcontrolled studyen
dc.subjectCroatiaen
dc.subjectenzyme linked immunosorbent assayen
dc.subjectEstoniaen
dc.subjectfluorescent enzyme immunoassayen
dc.subjectFranceen
dc.subjectGermanyen
dc.subjectGreeceen
dc.subjecthumanen
dc.subjectHungaryen
dc.subjectimmunoassayen
dc.subjectItalyen
dc.subjectlaboratoryen
dc.subjectmulticenter studyen
dc.subjectnephelometryen
dc.subjectNetherlandsen
dc.subjectNorwayen
dc.subjectquality controlen
dc.subjectquantitative assayen
dc.subjectSpainen
dc.subjectSwedenen
dc.subjectSwitzerlanden
dc.subjectturbidimetryen
dc.subjectUnited Kingdomen
dc.subjectclinical laboratory serviceen
dc.subjectclinical trialen
dc.subjectquality controlen
dc.subjectstandarden
dc.subjectAutoantibodiesen
dc.subjectClinical Laboratory Servicesen
dc.subjectHumansen
dc.subjectLaboratoriesen
dc.subjectQuality Controlen
dc.subjectReference Standardsen
dc.subjectDe Gruyter Open Ltden
dc.titleRepository of intra- and inter-run variations of quantitative autoantibody assays: A European multicenter studyen
dc.typejournalArticleen


Dateien zu dieser Ressource

DateienGrößeFormatAnzeige

Zu diesem Dokument gibt es keine Dateien.

Das Dokument erscheint in:

Zur Kurzanzeige