Εμφάνιση απλής εγγραφής

dc.creatorGourzoulidis G., Karabetsos E., Skamnakis N., Kappas C., Theodorou K., Tsougos I., Maris T.G.en
dc.date.accessioned2023-01-31T07:44:09Z
dc.date.available2023-01-31T07:44:09Z
dc.date.issued2015
dc.identifier10.1088/1742-6596/637/1/012009
dc.identifier.issn17426588
dc.identifier.urihttp://hdl.handle.net/11615/72660
dc.description.abstractMagnetic Resonance Imaging (MRI) systems played a crucial role in the postponement of the former occupational electromagnetic fields (EMF) European Directive (2004/40/EC) and in the formation of the latest exposure limits adopted in the new one (2013/35/EU). Moreover, the complex MRI environment will be finally excluded from the implementation of the new occupational limits, leading to an increased demand for Occupational Health and Safety (OHS) surveillance. The gradient function of MRI systems and the application of the RF excitation frequency result in low and high frequency exposures, respectively. This electromagnetic field exposure, in combination with the increased static magnetic field exposure, makes the MRI environment a unique case of combined EMF exposure. The electromagnetic field levels in close proximity of different MRI systems have been assessed at various frequencies. Quality Assurance (QA) & safety issues were also faced. Preliminary results show initial compliance with the forthcoming limits in each different frequency band, but also revealed peculiar RF harmonic components, of no safety concern, to the whole range detected (20-1000MHz). Further work is needed in order to clarify their origin and characteristics.en
dc.language.isoenen
dc.sourceJournal of Physics: Conference Seriesen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84945296159&doi=10.1088%2f1742-6596%2f637%2f1%2f012009&partnerID=40&md5=333f2f98cd6ea83c5ad68565cb740d96
dc.subjectElectromagnetic fieldsen
dc.subjectFrequency bandsen
dc.subjectIndustrial hygieneen
dc.subjectMagnetismen
dc.subjectQuality assuranceen
dc.subjectSafety engineeringen
dc.subjectDifferent frequencyen
dc.subjectElectromagnetic environmentsen
dc.subjectElectromagnetic field exposureen
dc.subjectHarmonic componentsen
dc.subjectLow and high frequenciesen
dc.subjectOccupational exposure assessmentsen
dc.subjectOccupational health and safetyen
dc.subjectStatic magnetic fieldsen
dc.subjectMagnetic resonance imagingen
dc.subjectInstitute of Physics Publishingen
dc.titleThe electromagnetic environment of Magnetic Resonance Imaging systems. Occupational exposure assessment reveals RF harmonicsen
dc.typeconferenceItemen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής