dc.description.abstractAim To evaluate apparent diffusion coefficient (ADC) measurements of breast lesions on different computer platforms to address post-processing influences on ADC measurement reproducibility. Materials and methods One hundred biopsy-proven breast lesions were included in this prospective study. MRI examination was performed at 3 T using standard sequences and an echo planar diffusion-weighted imaging sequence with b-values of 0 and 850 s/mm2. The images were reviewed by two radiologists in consensus. Regions of interest were placed manually within the lesion, following its contour. Care was taken to exclude adjacent normal tissue or necrotic tissue and cystic components within the lesion. The mean ADC value was measured for each lesion on two different platforms: On the MRI workstation that came with the scanner and on a commercially available DICOM (digital imaging and communication in medicine) viewer. Agreement between workstation measurements was evaluated using intraclass correlation coefficient and Bland–Altman plots. Results Fifty-nine malignant and 41 benign lesions were analysed. Of the benign lesions, 28 were mass lesions and 13 were non-mass-like enhancements. In addition, 46 of the malignant lesions were masses and 13 were non-mass-like enhancements. Agreement between the two workstation measurements was high (intraclass correlation coefficients=0.981). Using Bland–Altman plots, no systematic differences were identified between workstations. Limits of agreement ranged between a minimum of –0.071×10−3 mm2/s and a maximum of 0.102×10−3 mm2/s. Conclusion ADC measurements are reproducible among the workstations considered in this study. © 2017 The Royal College of Radiologistsen
dc.language.isoenen
dc.sourceClinical Radiologyen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85038406504&doi=10.1016%2fj.crad.2017.08.009&partnerID=40&md5=6fcdf5b66ef3f420d4cc5a1afa25950b
dc.subjectgadodiamideen
dc.subjectapparent diffusion coefficienten
dc.subjectArticleen
dc.subjectbland altman ploten
dc.subjectbreast biopsyen
dc.subjectbreast canceren
dc.subjectbreast carcinomaen
dc.subjectbreast cysten
dc.subjectbreast fibroadenomaen
dc.subjectbreast lesionen
dc.subjectbreast papillomaen
dc.subjectbreast tissueen
dc.subjectbreast tumoren
dc.subjectcancer tissueen
dc.subjectclinical evaluationen
dc.subjectcomputer assisted diagnosisen
dc.subjectconsensusen
dc.subjectcontrast enhancementen
dc.subjectcorrelation coefficienten
dc.subjectdiagnostic test accuracy studyen
dc.subjectdiagnostic valueen
dc.subjectdifferential diagnosisen
dc.subjectdiffusion weighted imagingen
dc.subjectdigital imaging and communications in medicineen
dc.subjectecho planar imagingen
dc.subjectfemaleen
dc.subjectfibrocystic breast diseaseen
dc.subjecthumanen
dc.subjectimage analysisen
dc.subjectimage enhancementen
dc.subjectimage processingen
dc.subjectintraductal carcinomaen
dc.subjectlimit of detectionen
dc.subjectlobular carcinoma in situen
dc.subjectmagnetic resonance mammographyen
dc.subjectmajor clinical studyen
dc.subjectmammographyen
dc.subjectnuclear magnetic resonance imagingen
dc.subjectpapillary carcinomaen
dc.subjectplots and curvesen
dc.subjectpriority journalen
dc.subjectradiologisten
dc.subjectreproducibilityen
dc.subjectretrospective studyen
dc.subjectsquamous cell carcinomaen
dc.subjecttissue necrosisen
dc.subjecttumor differentiationen
dc.subjecttumor necrosisen
dc.subjectbreasten
dc.subjectbreast tumoren
dc.subjectdevicesen
dc.subjectdiagnostic imagingen
dc.subjectproceduresen
dc.subjectprospective studyen
dc.subjectreproducibilityen
dc.subjectBreasten
dc.subjectBreast Neoplasmsen
dc.subjectDiffusion Magnetic Resonance Imagingen
dc.subjectEcho-Planar Imagingen
dc.subjectFemaleen
dc.subjectHumansen
dc.subjectImage Interpretation, Computer-Assisteden
dc.subjectMagnetic Resonance Imagingen
dc.subjectProspective Studiesen
dc.subjectReproducibility of Resultsen
dc.subjectRetrospective Studiesen
dc.subjectW.B. Saunders Ltden
dc.titleReproducibility of apparent diffusion coefficient measurements evaluated with different workstationsen
dc.typejournalArticleen


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem