Εμφάνιση απλής εγγραφής

dc.creatorXanthis, C. G.en
dc.creatorVenetis, I. E.en
dc.creatorAletras, A. H.en
dc.date.accessioned2015-11-23T10:54:15Z
dc.date.available2015-11-23T10:54:15Z
dc.date.issued2014
dc.identifier10.1186/1532-429x-16-48
dc.identifier.issn1097-6647
dc.identifier.urihttp://hdl.handle.net/11615/34692
dc.description.abstractBackground: MRI physics simulators have been developed in the past for optimizing imaging protocols and for training purposes. However, these simulators have only addressed motion within a limited scope. The purpose of this study was the incorporation of realistic motion, such as cardiac motion, respiratory motion and flow, within MRI simulations in a high performance multi-GPU environment. Methods: Three different motion models were introduced in the Magnetic Resonance Imaging SIMULator (MRISIMUL) of this study: cardiac motion, respiratory motion and flow. Simulation of a simple Gradient Echo pulse sequence and a CINE pulse sequence on the corresponding anatomical model was performed. Myocardial tagging was also investigated. In pulse sequence design, software crushers were introduced to accommodate the long execution times in order to avoid spurious echoes formation. The displacement of the anatomical model isochromats was calculated within the Graphics Processing Unit (GPU) kernel for every timestep of the pulse sequence. Experiments that would allow simulation of custom anatomical and motion models were also performed. Last, simulations of motion with MRISIMUL on single-node and multi-node multi-GPU systems were examined. Results: Gradient Echo and CINE images of the three motion models were produced and motion-related artifacts were demonstrated. The temporal evolution of the contractility of the heart was presented through the application of myocardial tagging. Better simulation performance and image quality were presented through the introduction of software crushers without the need to further increase the computational load and GPU resources. Last, MRISIMUL demonstrated an almost linear scalable performance with the increasing number of available GPU cards, in both single-node and multi-node multi-GPU computer systems. Conclusions: MRISIMUL is the first MR physics simulator to have implemented motion with a 3D large computational load on a single computer multi-GPU configuration. The incorporation of realistic motion models, such as cardiac motion, respiratory motion and flow may benefit the design and optimization of existing or new MR pulse sequences, protocols and algorithms, which examine motion related MR applications.en
dc.sourceJournal of Cardiovascular Magnetic Resonanceen
dc.source.uri<Go to ISI>://WOS:000341845800001
dc.subjectSPATIAL MODULATIONen
dc.subjectHEARTen
dc.subjectMAGNETIZATIONen
dc.subjectDEFORMATIONen
dc.subjectRESPIRATIONen
dc.subjectCardiac & Cardiovascular Systemsen
dc.subjectRadiology, Nuclear Medicine & Medicalen
dc.subjectImagingen
dc.titleHigh performance MRI simulations of motion on multi-GPU systemsen
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής