On environmental ground borne noise & vibration abatment by implemeting floating slabs at Athens metro network - Measurements campaign results

Thumbnail
Author
Vogiatzis, K.
Date
2011
Keyword
Environmental noise
Ground borne noise
Metro
Urban LRT operation
Vibration
environmental protection
floating structure
metro system
noise pollution
pollution control
structural component
transportation infrastructure
urban area
Athens [Attica]
Attica
Greece
Amyna
Metadata display
Abstract
This paper describes the FS implementation, on 4 major extensions of Athens Metro lines 2 and 3, already in service: (a) extension of line 2 from Sepolia to Ag.Antonios station, (b) extension of line 2 from Dafni to Ilioupoli (Ag. Dimitrios station), (c) extension of line 3 from Ethniki Amyna to Stavros (D.Plakentias station)and, extension of line 3 from Monastiraki to Egaleo. Ground borne noise and vibration mitigation measures evaluation in normal operation conditions presented hereafter guarantees, especially in TO location along these extensions, allowable ground borne noise and vibration levels in nearby buildings & sensitive receptors. The measured Floating slab solutions measured within an extensive measurements campaign proven to achieving an overall ground borne and vibration attenuation of approx.15-16 dB(A) in soil surface. A comprehensive comparative presentation of the results is an important tool in evaluating the expected environmental protection potential of similar mitigation measures regarding noise & vibration emissions & generated annoyance from urban railway networks operation.
URI
http://hdl.handle.net/11615/34586
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister (MyDspace)
Help Contact
DepositionAboutHelpContact Us
Choose LanguageAll of DSpace
EnglishΕλληνικά
htmlmap