A comparison of Monte Carlo simulation with experimental dosimetric techniques for a 6 MV stereotactic radiotherapy unit

Thumbnail
Author
Tsougos, I. M.; Theodorou, K.; Bazioglou, M. A.; Stathakis, S.; Kappas, C.
Date
2004
Keyword
Monte Carlo
Radiosurgery
Small field dosimetry
Sterotactic radiotherapy
accuracy
article
beam therapy
comparative study
computer
controlled study
dosimetry
electronics
Greece
ionization chamber
linear accelerator
Monte Carlo method
photon
radiation energy
radiation field
radiotherapy
reliability
standard
stereotaxis
university hospital
Metadata display
Abstract
Purpose: To compare Monte Carlo simulation with conventional dosimetry techniques for stereotactic radiotherapy (SRT), since accurate dosimetry of narrow photon beams is very complicated and has often been questioned, mainly due to the lack of lateral electronic equilibrium and uncertainty in beam energy in terms of steep dose gradients. Materials and methods: In this work a Monte Carlo (MC, EGS4) simulation for dosimerty study was performed for the 6MV home made SRT unit of the University Hospital of Patras (Hellas). The results were compared with conventional small field dosimetry techniques such as ionization chamber, TLD's, and films (conventional and radiochromic). Hence, a comparison of many of the dosimetric techniques currently being used in small field dosimetry was attempted. Results: It was shown that all techniques are in reasonable agreement (within ± 2%) and that Monte Carlo can be used as a reliable reference for the dosimetry of the SRT beams, especially where lateral electronic equilibrium does not exist, as long as accurate simulation can be achieved. Conclusion: This study is only limited by the insurance of accurate simulation of the linear accelerator, which can be a difficult task since it is limited by the availability of the manufacturer's designs and the availability of computers and computer time for adequate runs, but it could become a useful tool for Monte Carlo simulations, as it contains detailed analysis of the run parameters and component modules selection. © 2004 Zerbinis Medical Publications.
URI
http://hdl.handle.net/11615/34072
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister (MyDspace)
Help Contact
DepositionAboutHelpContact Us
Choose LanguageAll of DSpace
EnglishΕλληνικά
htmlmap