Mostra i principali dati dell'item

dc.creatorTsougos, I.en
dc.creatorGrout, I.en
dc.creatorTheodorou, K.en
dc.creatorKappas, C.en
dc.date.accessioned2015-11-23T10:52:21Z
dc.date.available2015-11-23T10:52:21Z
dc.date.issued2009
dc.identifier10.1080/09553000902748567
dc.identifier.issn0955-3002
dc.identifier.urihttp://hdl.handle.net/11615/34062
dc.description.abstractPurpose: The aim of this work was to develop a user-friendly and simple tool for fast and accurate estimation of Normal Tissue Complication Probabilities (NTCP) for several radiobiological models, which can be used as a valuable complement to the clinical experience. Materials and methods: The software which has been named DORES (Dose Response Evaluation Software) has been developed in Visual Basic, and includes three NTCP models (Lyman-Kuther-Burman (LKB), Relative Seriality and Parallel). Required input information includes the Dose-Volume Histogram (DVH) for the Organs at Risk (OAR) of each treatment, the number of fractions and the total dose of therapy. Results: NTCP values are computed, and subsequently placed in a spreadsheet file for further analysis. A Dose Response curve for every model is automatically generated. Every patient of the study population can be found on the curve since by definition their corresponding dose-response points fall exactly on the theoretical dose-response curve, when plotted on the same diagram. Conclusion: Distributions of absorbed dose alone do not provide information on the biological response of tissues to irradiation, so the use of this software may aid in the comparison of outcomes for different treatment plans or types of treatment, and also aid the evaluation of the sensitivity of different model predictions to uncertainties in parameter values. This was illustrated in a clinical case of breast cancer radiotherapy.en
dc.sourceInternational Journal of Radiation Biologyen
dc.source.uri<Go to ISI>://WOS:000265332800004
dc.subjectRadiotherapyen
dc.subjectprediction of normal tissue effecten
dc.subjectradiobiologicalen
dc.subjectmodellingen
dc.subjectTISSUE COMPLICATION PROBABILITYen
dc.subjectRADIATION-INDUCED PNEUMONITISen
dc.subjectRELATIVELY SERIAL STRUCTUREen
dc.subjectVOLUME HISTOGRAMen
dc.subjectCANCER RADIOTHERAPYen
dc.subjectPULMONARY-FUNCTIONen
dc.subjectTHERAPYen
dc.subjectOPTIMIZATIONen
dc.subjectIRRADIATIONen
dc.subjectTUMORen
dc.subjectBiologyen
dc.subjectNuclear Science & Technologyen
dc.subjectRadiology, Nuclear Medicine &en
dc.subjectMedical Imagingen
dc.titleA free software for the evaluation and comparison of dose response models in clinical radiotherapy (DORES)en
dc.typejournalArticleen


Files in questo item

FilesDimensioneFormatoMostra

Nessun files in questo item.

Questo item appare nelle seguenti collezioni

Mostra i principali dati dell'item