Logo
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Ελληνικά 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Σύνδεση
Προβολή τεκμηρίου 
  •   Ιδρυματικό Αποθετήριο Πανεπιστημίου Θεσσαλίας
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Προβολή τεκμηρίου
  •   Ιδρυματικό Αποθετήριο Πανεπιστημίου Θεσσαλίας
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Προβολή τεκμηρίου
JavaScript is disabled for your browser. Some features of this site may not work without it.
Ιδρυματικό Αποθετήριο Πανεπιστημίου Θεσσαλίας
Όλο το DSpace
  • Κοινότητες & Συλλογές
  • Ανά ημερομηνία δημοσίευσης
  • Συγγραφείς
  • Τίτλοι
  • Λέξεις κλειδιά

Comparison of three skin-stretching devices for closing skin defects on the limbs of dogs

Thumbnail
Συγγραφέας
Tsioli, V.; Papazoglou, L. G.; Papaioannou, N.; Psalla, D.; Savvas, I.; Pavlidis, L.; Karayannopoulpou, M.
Ημερομηνία
2015
DOI
10.4142/jvs.2015.16.1.99
Λέξη-κλειδί
Dog
Extremities
Skin defects
Skin stretchers
Εμφάνιση Μεταδεδομένων
Επιτομή
Our objective was to evaluate the effectiveness of skin-stretching devices for closing defects on the extremities of dogs. Antebrachial skin defects were created on the limbs of 24 dogs randomly divided into three groups. Skin stretchers included staples and sutures passing through them (group A), sutures and hypodermic needles (group B), and Pavletic device (group C). Wounds on the left were further undermined in all groups. Tension and blood perfusion were assessed. After removing the stretchers on day 3, the defects were sutured and wound healing was clinically scored. Histological variables evaluated were cellular infiltration, edema, collagen orientation, and thickness of epidermis. Significant differences in tension were found among groups (p < 0.0005) and between measurement times for undermined (p = 0.001) or non-undermined (p < 0.0005) wounds. In contrast, blood perfusion values did not differ significantly. Clinical scores for group B seemed to be better than those for groups A and C, but differences were not significant. Primary wound closure using the Pavletic device was not feasible. No significant differences in histological variables were found between groups. Skin stretching with staples or hypodermic needles resulted in successful wound management with minor side effects on skin histology and circulation. © 2015 The Korean Society of Veterinary Science.
URI
http://hdl.handle.net/11615/33963
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Πλοήγηση

Όλο το DSpaceΚοινότητες & ΣυλλογέςΑνά ημερομηνία δημοσίευσηςΣυγγραφείςΤίτλοιΛέξεις κλειδιάΑυτή η συλλογήΑνά ημερομηνία δημοσίευσηςΣυγγραφείςΤίτλοιΛέξεις κλειδιά

Ο λογαριασμός μου

ΣύνδεσηΕγγραφή (MyDSpace)
Πληροφορίες-Επικοινωνία
ΑπόθεσηΣχετικά μεΒοήθειαΕπικοινωνήστε μαζί μας
Επιλογή ΓλώσσαςΌλο το DSpace
EnglishΕλληνικά
htmlmap