Reduction of radiation doses to patients and staff during endoscopic retrograde cholangiopancreatography

Thumbnail
Autor
Sulieman, A.; Paroutoglou, G.; Kapsoritakis, A.; Kapatenakis, A.; Potamianos, S.; Vlychou, M.; Theodorou, K.
Datum
2011
DOI
10.4103/1319-3767.74456
Schlagwort
ERCP
radiation risk
staff exposure
DIAGNOSTIC-RADIOLOGY
EXPOSURE
FLUOROSCOPY
CYSTOURETHROGRAPHY
PERSONNEL
RISKS
Gastroenterology & Hepatology
Zur Langanzeige
Zusammenfassung
Background/Aim: Endoscopic retrograde cholangiopancreatography (ERCP) is associated with a considerable radiation exposure for patients and staff. While optimization of the radiation dose is recommended, few studies have been published. The purpose of this study has been to measure patient and staff radiation dose, to estimate the effective dose and radiation risk using digital fluoroscopic images. Entrance skin dose (ESD), organ and effective doses were estimated for patients and staff. Materials and Methods: Fifty-seven patients were studied using digital X-ray machine and thermoluminescent dosimeters (TLD) to measure ESD at different body sites. Organ and surface dose to specific radiosensitive organs was carried out. The mean, median, minimum, third quartile and the maximum values are presented due to the asymmetry in data distribution. Results: The mean ESD, exit and thyroid surface dose were estimated to be 75.6 mGy, 3.22 mGy and 0.80 mGy, respectively. The mean effective dose for both gastroenterologist and assistant is 0.01 mSv. The mean patient effective dose was 4.16 mSv, and the cancer risk per procedure was estimated to be 2 x 10 (-5) . Conclusion: ERCP with fluoroscopic technique demonstrate improved dose reduction, compared to the conventional radiographic based technique, reducing the surface dose by a factor of 2, without compromising the diagnostic findings. The radiation absorbed doses to the different organs and effective doses are relatively low.
URI
http://hdl.handle.net/11615/33476
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

EinloggenRegistrieren
Help Contact
DepositionAboutHelpKontakt
Choose LanguageGesamter Bestand
EnglishΕλληνικά
htmlmap