• English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • español 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Login
Ver ítem 
  •   DSpace Principal
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Ver ítem
  •   DSpace Principal
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.
Todo DSpace
  • Comunidades & Colecciones
  • Por fecha de publicación
  • Autores
  • Títulos
  • Materias

DIFFERENCES BETWEEN ARMS AND LEGS ON POSITION SENSE AND JOINT REACTION ANGLE

Thumbnail
Autor
Paschalis, V.; Nikolaidis, M. G.; Giakas, G.; Jamurtas, A. Z.; Koutedakis, Y.
Fecha
2009
DOI
10.1519/JSC.0b013e3181b4382d
Materia
lower limb
proprioception
reaction time
upper limb
MUSCLES
Sport Sciences
Mostrar el registro completo del ítem
Resumen
Paschalis, V, Nikolaidis, MG, Giakas, G, Jamurtas, AZ, and Koutedakis, Y. Differences between arms and legs on position sense and joint reaction angle. J Strength Cond Res 23(6): 1652-1655, 2009-The purpose of the present investigation was to compare the arms and legs in relation to position sense and joint reaction angle. Position sense at 30 degrees, 45 degrees, and 60 degrees flexion as well as joint reaction angle to release from 20 degrees, 40 degrees, and 60 degrees flexion of the elbow and knee joint were evaluated in 12 healthy men. The measurements were performed over 3 consecutive days to minimize the error attributable to the variability of the measured parameters. During the assessment of position sense, subjects had to place their limb as closely as possible to the reference angle. The joint reaction angle was measured by a new test in which the subjects had to stop the fall of their limb as soon as possible after it was released. All measurements were performed in a common isokinetic dynamometer. The results of position sense showed that the arms were placed closer to the reference angle compared with the legs (1.3 degrees vs. 3.1 degrees on average for 3 angles, respectively; p < 0.05). The arms also exhibited faster reaction angle to release compared with legs (3.4 degrees vs. 6.3 degrees on average for 3 angles, respectively; p < 0.05). In conclusion, the ability of arms to perform more accurate and faster movements than legs may mainly be attributed to the higher number of muscle spindles and the lower innervation ratio of arms. An imbalance of the determined relationship between arms and legs in position sense and reaction angle may indicate a neuromuscular disturbance.
URI
http://hdl.handle.net/11615/32059
Colecciones
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro
Help Contact
DepositionAboutHelpContacto
Choose LanguageTodo DSpace
EnglishΕλληνικά
htmlmap