Εμφάνιση απλής εγγραφής

dc.creatorMouchtouri, V.en
dc.creatorVelonakis, E.en
dc.creatorTsakalof, A.en
dc.creatorKapoula, C.en
dc.creatorGoutziana, G.en
dc.creatorVatopoulos, A.en
dc.creatorKremastinou, J.en
dc.creatorHadjichristodoulou, C.en
dc.date.accessioned2015-11-23T10:39:55Z
dc.date.available2015-11-23T10:39:55Z
dc.date.issued2007
dc.identifier10.1128/aem.02192-06
dc.identifier.issn0099-2240
dc.identifier.urihttp://hdl.handle.net/11615/31143
dc.description.abstractThe Legionella colonization frequency at 385 Greek hotel hot and cold water distribution systems was 20.8%. Legionella contamination was associated with the presence of an oil heater (odds ratio [OR] = 2.04, 95% confidence interval [CI] = 1.12 to 3.70), with the sample temperature (OR = 0.26, 95% CI = 0.1 to 0.5), with seasonal operation (OR = 3.23, 95% CI = 1.52 to 6.87), and with the presence of an independent disinfection system (OR = 0.30, 95% CI = 0.15 to 0.62). The same water temperatures, free-chlorine levels, and pHs differently affect the survival of various Legionella spp.en
dc.sourceApplied and Environmental Microbiologyen
dc.source.uri<Go to ISI>://WOS:000245068900013
dc.subjectPARA-OLYMPIC GAMESen
dc.subjectCOLONIZATIONen
dc.subjectBiotechnology & Applied Microbiologyen
dc.subjectMicrobiologyen
dc.titleRisk factors for contamination of hotel water distribution systems by Legionella speciesen
dc.typejournalArticleen