Prediction of AVM obliteration after stereotactic radiotherapy using radiobiological modelling

Thumbnail
Auteur
Mavroidis, P.; Theodorou, K.; Lefkopoulos, D.; Nataf, F.; Schlienger, M.; Karlsson, B.; Lax, I.; Kappas, C.; Lind, B. K.; Brahme, A.
Date
2002
DOI
10.1088/0031-9155/47/14/308
Sujet
CEREBRAL ARTERIOVENOUS-MALFORMATIONS
LINEAR-ACCELERATOR RADIOSURGERY
CONFORMAL RADIATION-THERAPY
GAMMA-KNIFE RADIOSURGERY
DOSE-RESPONSE
ANALYSIS
NORMAL TISSUE
COMPLICATIONS
PROBABILITY
VOLUME
TUMOR
Engineering, Biomedical
Radiology, Nuclear Medicine & Medical Imaging
Afficher la notice complète
Résumé
This study was carried out in order to derive the radiobiological parameters of the dose-response relation for the obliteration of arteriovenous malformation (AVM) following single fraction stereotactic radiotherapy. Furthermore, the accuracy by which the linear Poisson model predicts the probability of obliteration and how the haemorrhage history, location and volume of the AVM influence its radiosensitivity are investigated. The study patient material consists of 85 patients who received radiation for AVM therapy. Radiation-induced AVM obliterations were assessed on the basis of postirradiation angiographies and other radiological findings. For each patient the dose delivered to the clinical target volume and the clinical treatment outcome were available. These data were used in a maximum likelihood analysis to calculate the best estimates of the parameters of the linear Poisson model. The uncertainties of these parameters were also calculated and their individual influence on the dose-response curve was studied. AVM radiosensitivity was assumed to be the same for all the patients. The radiobiological model used was proved suitable for predicting the treatment outcome pattern of the studied patient material. The radiobiological parameters of the model were calculated for different AVM locations, bleeding histories and AVM sizes. The range of parameter variability had considerable effect on the dose-response curve of AVM. The correlation between the dosimetric data and their corresponding clinical effect could be accurately modelled using the linear Poisson model. The derived response parameters can be introduced into the clinical routine with the calculated accuracy assuming the same methodology in target definition and delineation. The known volume dependence of AVM radiosensitivity was confirmed. Moreover, a trend relating AVM location with its radiosensitivity was observed.
URI
http://hdl.handle.net/11615/30830
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une sessionS'inscrire
Help Contact
DepositionAboutHelpContactez-nous
Choose LanguageTout DSpace
EnglishΕλληνικά
htmlmap