Residue screening in apple, grape and wine food samples for seven new pesticides using HPLC with UV detection. An application to trifloxystrobin dissipation in grape and wine

Thumbnail
Autor
Likas, D. T.; Tsiropoulos, N. G.
Fecha
2009
DOI
10.1080/03067310902756615
Materia
food analysis
liquid chromatography
fungicides
insecticides
uncertainty
SOLID-PHASE EXTRACTION
DIODE-ARRAY DETECTION
PERFORMANCE
LIQUID-CHROMATOGRAPHY
TANDEM MASS-SPECTROMETRY
BENZOYLUREA
INSECTICIDES
RED WINES
FUNGICIDES
FAMOXADONE
FATE
VALIDATION
Chemistry, Analytical
Environmental Sciences
Mostrar el registro completo del ítem
Resumen
A new analytical procedure was developed and validated, using liquid chromatography, for simultaneous determination of seven new pesticides belonging to different chemical classes (azoles, strobilurines, benzoylureas, and a new oxazolidinedione) in apple, grape and wine food samples. Solvent extraction of pesticides was performed using a cyclohexane-dichloromethane (9 + 1 v/v) mixture and the extract was cleaned-up by solid-phase extraction (SPE) using silica cartridges and elution with tetrahydrofurane. Separation of pesticides flusilazole, fenbuconazole, diniconazole, tebufenozide, famoxadone, trifloxystrobin and flufenoxuron was performed by gradient elution High-Performance Liquid Chromatography (HPLC) with a microbore Hypersil HS C18 column in 35 min total time, using mixtures of acetonitrile-water as the mobile phase. Pesticides were detected and quantified at 210 nm with a variable-wavelength UV detector. Recoveries of pesticides from spiked samples, at 0.05-2.0 mg kg-1 for apple and grape and at 0.025-0.250 mg L-1 for wine, ranged from 82 to 107% for apple and grape and from 87% to 106% for wine with RSD 12%. The limits of quantification (LOQs) of the method, as a signal to noise ratio equalled 10, ranged from 0.02 to 0.10 mg kg-1 for apple and grape and from 0.005 to 0.02 mg L-1 for wine samples. The uncertainty associated with the analytical methodology, estimated using the 'bottom-up' approach, was lower than 12.8% for all pesticides and matrices tested. The proposed methodology was applied for the evaluation of trifloxystrobin residue levels in grapes exposed to field treatments and in the must and wine produced from them.
URI
http://hdl.handle.net/11615/30364
Colecciones
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro
Help Contact
DepositionAboutHelpContacto
Choose LanguageTodo DSpace
EnglishΕλληνικά
htmlmap