dc.identifier10.1016/j.mri.2013.06.007
dc.identifier.issn0730-725X
dc.identifier.urihttp://hdl.handle.net/11615/30213
dc.description.abstractThe purpose of this study, is to compare the sequences: 1) proton density (PD) BLADE (BLADE is a PROPELLER-equivalent implementation of the Siemens Medical System) with fat saturation (FS) coronal (COR), 2) PD FS COR, 3) multi-planar reconstruction (MPR) with 3 mm slice thickness and 4) multi-planar reconstruction (MPR) with 1.5 mm slice thickness, both from the T2 3D-double-echo steady state (DESS) with water excitation (WE) sagittal (SAG), regarding their abilities to identify changes in the femorotibial condyle cartilage in knee MRI examinations. Thirty three consecutive patients with osteoarthritis (18 females, 15 males; mean age 56 years, range 37-71 years), who had been routinely scanned for knee examination using the previously mentioned image acquisition techniques, participated in the study. A quantitative analysis was performed based on the relative contrast (ReCON) measurements, which were taken both on normal tissues as well as on pathologies. Additionally, a qualitative analysis was performed by two radiologists. Motion and pulsatile flow artifacts were evaluated. The PD BLADE FS COR sequence produced images of higher contrast between Menisci and Cartilage, Fluid and Cartilage, Pathologies and Cartilage as well as of the Conspicuousness Superficial Cartilage and it was found to be superior to the other sequences (p < 0.001). The sequences T2 3D DESS 1.5 mm and T2 3D DESS 3 mm were significantly superior to the PD BLADE FS COR and the PD FS COR sequences in the visualization of Bone and Cartilage and the Conspicuousness Deep Surface Cartilage. This pattern of results is also confirmed by the quantitative analysis. PD FS BLADE sequences are ideal for the depiction of the cartilage pathologies compared to the conventional PD FS and 12 3D DESS sequences. (C) 2013 Elsevier Inc. All rights reserved.en
dc.source.uri<Go to ISI>://WOS:000324609000001
dc.subject1.5 T MRIen
dc.subjectKnee MRIen
dc.subjectBLADE proton density with fat saturation sequencesen
dc.subjectCartilage defectsen
dc.subjectT2 3D DESSen
dc.subjectSTEADY-STATE DESSen
dc.subjectARTHROSCOPIC CORRELATIONen
dc.subjectHYALINE CARTILAGEen
dc.subjectMENISCALen
dc.subjectTEARSen
dc.subjectECHO SEQUENCEen
dc.subjectDUAL-ECHOen
dc.subjectOSTEOARTHRITISen
dc.subjectAPPEARANCEen
dc.subjectMRIen
dc.subjectARTIFACTSen
dc.subjectRadiology, Nuclear Medicine & Medical Imagingen
dc.titleComparison of PD BLADE with fat saturation (FS), PD FS and T2 3D DESS with water excitation (WE) in detecting articular knee cartilage defectsen