• English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • français 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Ouvrir une session
Voir le document 
  •   Accueil de DSpace
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Voir le document
  •   Accueil de DSpace
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Voir le document
JavaScript is disabled for your browser. Some features of this site may not work without it.
Tout DSpace
  • Communautés & Collections
  • Par date de publication
  • Auteurs
  • Titres
  • Sujets

Development of a Portable Anchored Dynamometer for Collection of Maximal Voluntary Isometric Contractions in Biomechanics Research on Dancers

Thumbnail
Auteur
Krasnow, D.; Ambegaonkar, J. P.; Stecyk, S.; Wilmerding, M. V.; Wyon, M.; Koutedakis, Y.
Date
2011
Sujet
HAND-HELD DYNAMOMETRY
MUSCLE STRENGTH
ELECTROMYOGRAPHIC ANALYSIS
DEMI-PLIE
RELIABILITY
BALLET
COORDINATION
STRATEGY
HEALTHY
STATION
Medicine, General & Internal
Music
Afficher la notice complète
Résumé
Surface electromyography (sEMG) has been used in dance medicine research since the 1970s, but normalization procedures are not consistently employed in the field. The purpose of this project was to develop a portable anchored dynamometer (PAD) specifically for dance-related research. Due to the limited studies in the dance research literature using normalization procedures for sEMG data, a review of the procedures used in the exercise science literature was conducted. A portable anchored dynamometer was then developed and tested with dancers, using methods validated in previous literature. We collected sEMG maximum voluntary isometric contractions (MVIC, mV) from 10 female dancers (mean age 31.0 +/- 15 yrs, mean height 1.63 +/- 7.6 cm, mean weight 57.6 +/- 6.9 kg, and 17.0 +/- 13.9 yrs of training in ballet and/or modern dance) over three trials (5 sec each) for eight muscles bilaterally (quadriceps, tibialis anterior, abductor hallucis, gastrocnemius, hamstrings, gluteus maximus, erector spinae, and rectus abdominus). Consistency of data and feedback from dancers suggest that this dance-specific portable anchored dynamometer is effective for future sEMG studies in dance research. Medical Problems of Performing Artists 2011; 26(4)185-194.
URI
http://hdl.handle.net/11615/30022
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une sessionS'inscrire
Help Contact
DepositionAboutHelpContactez-nous
Choose LanguageTout DSpace
EnglishΕλληνικά
htmlmap