• English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Deutsch 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Einloggen
Dokumentanzeige 
  •   DSpace Startseite
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Dokumentanzeige
  •   DSpace Startseite
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.
Gesamter Bestand
  • Bereiche & Sammlungen
  • Erscheinungsdatum
  • Autoren
  • Titeln
  • Schlagworten

Development and evaluation of a DSS for drainage management in semi-closed hydroponic systems

Thumbnail
Autor
Katsoulas, N.; Kittas, C.; Bartzanas, T.; Savvas, D.
Datum
2014
Schlagwort
Crop water consumption
Greenhouse
Nutrient solution management
Tomato
Zur Langanzeige
Zusammenfassung
The recycling of greenhouse effluents in soilless cultivation systems is environment-friendly, since the waste of water and the disposal of nutrients to the environment is drastically reduced or even eliminated. However, a long-term recycling of the effluents may result in accumulation of Na+ and Cl- in the recycled nutrient solution. The major aim of the present research was to test the performance of a Na+ mass balance model operating as part of a decision support system in a tomato crop grown in a closed-loop hydroponic system. Three treatments were compared: a completely open, a completely closed and a semi-closed hydroponic system during one experimental period lasting from October 2011 to January 2012. The fresh water used for the preparation of the nutrient solution contained 2 mM NaCl. During the total experimental period, the water uptake by the crop was relatively low, near to 130 L m-2, and thus, the concentration of Na+ in the closed system did not surpass the level of about 20 mM during the total experimental period. Comparison between measured and simulated Na+ values gave fair results. The system was efficient at minimizing the discharge of nutrient solution effluents in semi-closed hydroponic systems, thereby maximizing the water use efficiency.
URI
http://hdl.handle.net/11615/29281
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

EinloggenRegistrieren
Help Contact
DepositionAboutHelpKontakt
Choose LanguageGesamter Bestand
EnglishΕλληνικά
htmlmap