Εμφάνιση απλής εγγραφής

dc.creatorKarachalios, T.en
dc.creatorScambardonis, D.en
dc.creatorKhaldi, L.en
dc.creatorRaptou, P.en
dc.creatorPapagelopoulos, P. J.en
dc.creatorNikiforidis, P. A.en
dc.creatorLyritis, G.en
dc.date.accessioned2015-11-23T10:32:52Z
dc.date.available2015-11-23T10:32:52Z
dc.date.issued2000
dc.identifier.issn0147-7447
dc.identifier.urihttp://hdl.handle.net/11615/28935
dc.description.abstractThe biological and mechanical behavior of loaded cortical autografts were evaluated in an experimental study using 40 adult male New Zealand rabbits divided into 4 groups. A double osteotomy was performed on all animals at the mid-diaphysis of the right ulna. The bone segment (5 mm) in between the osteotomies was considered a cortical autograft and fixed with an intramedullary Kirschner wire. The graft was fixed in an orthotopic manner in groups A and C, and rotated 180 degrees in groups B and D. After the animals were sacrificed (at 2 months for groups A and B and at 4 months for groups C and D), bone mineral density, graft cross-sectional geometry, and SSI index were assessed. Mechanical testing of the grafted area was carried out using a three-point bending configuration, and the parameter fracture load was assessed. Graft union and incorporation also was studied in histologic sections. In group C (orthotopic graft placement - 4 months), bone specimens showed statistically significantly higher values for fracture load, total cross-sectional area, volumetric total bone mass and density, and polar SSI (P values less than or equal to.05) compared to the other groups. In the same group, union and incorporation of the graft was complete, the cortex showed low porosity, and the collagen fibers were mature and properly oriented. Structural cortical bone autografts placed in an orthotopic manner recognize the new mechanical environment as optimal and thus their biological and mechanical behavior are enhanced. Loaded structural cortical grafts should be placed in an orthotopic manner when used for the management of cortical bone defects.en
dc.sourceOrthopedicsen
dc.source.uri<Go to ISI>://WOS:000088734600012
dc.subjectTOTAL HIP-ARTHROPLASTYen
dc.subjectBONE-GRAFTSen
dc.subjectALLOGRAFTSen
dc.subjectRECONSTRUCTIONen
dc.subjectFRACTURESen
dc.subjectFEMURen
dc.subjectSTOCKen
dc.subjectOrthopedicsen
dc.titleInfluence of orthotopic placement on the incorporation and mechanical strength of a loaded structural cortical graft: An experimental study in rabbitsen
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής