Afficher la notice abrégée

dc.creatorHantes, M. E.en
dc.creatorBasdekis, G. K.en
dc.creatorVaritimidis, S. E.en
dc.creatorGiotikas, D.en
dc.creatorPetinaki, E.en
dc.creatorMalizos, K. N.en
dc.date.accessioned2015-11-23T10:29:52Z
dc.date.available2015-11-23T10:29:52Z
dc.date.issued2008
dc.identifier10.2106/jbjs.g.00806
dc.identifier.issn0021-9355
dc.identifier.urihttp://hdl.handle.net/11615/28414
dc.description.abstractBackground: The autograft preparation process for anterior cruciate ligament reconstruction has a potential for graft contamination. The purpose of this study was to evaluate the possibility of contamination of the bone-patellar tendon-bone and hamstring tendon autograft during preparation for anterior cruciate ligament reconstruction. Methods: A primary isolated reconstruction of the anterior cruciate ligament with use of bone-patellar tendon-bone autograft (thirty patients) and hamstring tendon autograft (thirty patients) was performed in a prospective, consecutive series of patients. Three tissue samples were obtained for culture from each graft at different time-intervals during the graft preparation. In addition, the erythrocyte sedimentation rate and the C-reactive protein level were evaluated preoperatively and on the third, seventh, and twentieth postoperative days, and the clinical course of all patients was monitored. Results: The time needed for graft preparation was significantly longer for hamstring autografts (nineteen minutes) than for bone-patellar tendon-bone autografts (ten minutes) (p = 0.032). In the hamstring group, cultures of graft tissue from four patients (13%) were positive for bacteria. In the bone-patellar tendon-bone group, cultures of graft tissue from three patients (10%) were positive for bacteria; the difference between groups was not significant (p = 0.923). No patient had development of a postoperative infection. There were no differences between patients with a contaminated graft and those with an uncontaminated graft with regard to postoperative changes in the erythrocyte sedimentation rate or the C-reactive protein level at all time-intervals. Conclusions: A high rate (12%) of autograft contamination can be expected during autograft preparation for anterior cruciate ligament reconstruction. The contamination rate is almost equal for both bone-patellar tendon-bone and hamstring tendon autografts. We could not identify an association between contaminated grafts implanted in the knee and postoperative inflammatory markers such as the erythrocyte sedimentation rate and the C-reactive protein level. Level of Evidence: Therapeutic Level II. See Instructions to Authors for a complete description of levels of evidence.en
dc.source.uri<Go to ISI>://WOS:000254656500011
dc.subjectC-REACTIVE PROTEINen
dc.subjectTOTAL HIP ARTHROPLASTIESen
dc.subjectSEPTIC ARTHRITISen
dc.subjectMUSCULOSKELETAL ALLOGRAFTSen
dc.subjectACL-RECONSTRUCTIONen
dc.subjectCENTRAL GREECEen
dc.subjectINFECTIONen
dc.subjectGRAFTSen
dc.subjectMANAGEMENTen
dc.subjectDIAGNOSISen
dc.subjectOrthopedicsen
dc.subjectSurgeryen
dc.titleAutograft contamination during preparation for anterior cruciate ligament reconstructionen
dc.typejournalArticleen


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée