• English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • français 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Ouvrir une session
Voir le document 
  •   Accueil de DSpace
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Voir le document
  •   Accueil de DSpace
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Voir le document
JavaScript is disabled for your browser. Some features of this site may not work without it.
Tout DSpace
  • Communautés & Collections
  • Par date de publication
  • Auteurs
  • Titres
  • Sujets

The acute effects of different whole-body vibration amplitudes and frequencies on flexibility and vertical jumping performance

Thumbnail
Auteur
Gerodimos, V.; Zafeiridis, A.; Karatrantou, K.; Vasilopoulou, T.; Chanou, K.; Pispirikou, E.
Date
2010
DOI
10.1016/j.jsams.2009.09.001
Sujet
Squat jump
Sit and reach
Neuromuscular performance
Power
Dose-response
RANDOMIZED CROSS-OVER
MUSCULAR PERFORMANCE
MUSCLE PERFORMANCE
EXPLOSIVE STRENGTH
EXERCISE
POWER
STIMULATION
DURATION
ELITE
ENHANCEMENT
Sport Sciences
Afficher la notice complète
Résumé
Frequency and amplitude determine the training load of whole-body vibration (WBV) exercise and thereby possible neuromuscular adaptations. We investigated the effects of amplitude and frequency of a single bout of WBV on flexibility and squat jump performance (SJ) and the time-course of these effects. In the amplitude study, twenty-five females performed three vibration protocols (VPs) for 6 min at frequency of 25 Hz and amplitudes of 4 mm, 6 mm, and 8 mm and one control protocol (CP). In the frequency study, eighteen females performed three VPs at 6 mm amplitude and frequencies of 15 Hz, 20 Hz, and 30Hz and one CP. Flexibility and SJ were measured before, immediately-post and 15 min recovery. All protocols were performed on a side-to-side alternating vibration plate. In the amplitude study, flexibility was improved (p < 0.01) immediately-post in VP4, VP6, VP8 (31.8 +/- 8.2, 31.9 +/- 7.6, 31.5 +/- 7.9, respectively) and at 15 min recovery (31.6 +/- 8.1, 31.5 +/- 7.9, 31.0 +/- 8.2, respectively) vs. pre-vibration (30.2 +/- 8.6, 30.3 +/- 8.1, 30.2 +/- 8.3, respectively), but remained unchanged in CP (30.6 +/- 8.3 immediately-post, 30.7 +/- 8.2 at 15 min vs. 30.4 +/- 8.2 pre-vibration). In the frequency study, flexibility was improved (p < 0.01) immediately-post in VP15, VP20, VP30 (31.5 +/- 5.2, 31.3 +/- 5, 31.7 +/- 5.3, respectively) and at 15 min recovery (31.3 +/- 5.4, 31.3 +/- 5.0, 31.3 +/- 5.3, respectively) vs. pre-vibration (30.6 +/- 5.4, 30.2 +/- 5.7, 30.3 +/- 5.9, respectively), but not in CP (30.7 +/- 5.1 immediately-post, 30.6 +/- 5 at 15 min vs. pre-vibration 30.5 +/- 5.7). There were no significant effects of amplitude or frequency on SJ. In conclusion, a single WBV bout using a side-to-side alternating vibration plate may increase flexibility which persists for at least 15 min, without altering jumping performance. These effects were observed irrespective of frequency and amplitude. (C) 2009 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
URI
http://hdl.handle.net/11615/27808
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une sessionS'inscrire
Help Contact
DepositionAboutHelpContactez-nous
Choose LanguageTout DSpace
EnglishΕλληνικά
htmlmap