Logo
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • English 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Login
View Item 
  •   University of Thessaly Institutional Repository
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • View Item
  •   University of Thessaly Institutional Repository
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
Institutional repository
All of DSpace
  • Communities & Collections
  • By Issue Date
  • Authors
  • Titles
  • Subjects

Initial results on SiPMs performance for use in medical imaging

Thumbnail
Author
Efthimiou, N.; Georgiou, M.; Argyropoulos, G.; Fysikopoulos, E.; David, S.; Loudos, G.; Panayiotakis, G.
Date
2011
DOI
10.1088/0957-0233/22/11/114001
Keyword
SiPMT
pulse characteristics
spectral analysis
PHOTON COUNTERS MPPC
SILICON PHOTOMULTIPLIERS
PET
SCINTILLATORS
DETECTORS
Engineering, Multidisciplinary
Instruments & Instrumentation
Metadata display
Abstract
Silicon photomultiplier (SiPMs) detectors are attractive candidates for replacing position sensitive photomultipliers in nuclear imaging. They are compact, they provide high gain with low bias voltage and show better response. The development of dedicated imaging prototypes based on SiPMs possesses several design challenges, since it is necessary to optimize scintillator and SiPM coupling, as well as signal amplification and digitization. In this work, we have investigated the performance of three SiPM modules constructed by SensL coupled on three scintillators (CsI:Tl, BGO, LYSO:Ce), which are used in SPECT and PET imaging. Irradiation was carried out using different sources, which covered a wide range of energies from 88 to 1275 keV. The parameters measured were output pulses' width and height, energy resolution and linearity as a function of bias voltage and sources energy.
URI
http://hdl.handle.net/11615/27291
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister (MyDspace)
Help Contact
DepositionAboutHelpContact Us
Choose LanguageAll of DSpace
EnglishΕλληνικά
htmlmap