• English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • français 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Ouvrir une session
Voir le document 
  •   Accueil de DSpace
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Voir le document
  •   Accueil de DSpace
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Voir le document
JavaScript is disabled for your browser. Some features of this site may not work without it.
Tout DSpace
  • Communautés & Collections
  • Par date de publication
  • Auteurs
  • Titres
  • Sujets

Design considerations for application of SiPMs in nuclear imaging

Thumbnail
Auteur
Efthimiou, N.; Argyropoulos, G.; Georgiou, M.; Fysikopoulos, E.; David, S.; Loudos, G.; Panayiotakis, G.
Date
2010
DOI
10.1109/NSSMIC.2010.5874286
Sujet
Cs energies
Design challenges
Design considerations
Energy resolutions
Fast response
High gain
Nuclear imaging
Scintillator materials
Signal amplifications
Silicon photomultiplier
Strong magnetic fields
Cesium
Gamma rays
Magnetic fields
Nuclear physics
Photomultipliers
Scintillation
Semiconducting silicon
Signal processing
Silicon detectors
Medical imaging
Afficher la notice complète
Résumé
Silicon Photomultiplier (SiPM) detectors are attractive candidates for the replacement of Photomultipliers in nuclear imaging. They are compact, provide high gain with low Vbias and have fast response. In addition, SiPMs are not influenced by strong magnetic fields, allowing their use in the emerging field of PET-MRI. The development of small prototypes based on SiPMs posses several design challenges, since it is necessary to optimize scintillator and SiPM coupling, as well as signal amplification and digitization. The aim of this work is the characterization of two SiPM modules, in terms of energy resolution using 3 different scintillator materials and variable Vbias. We have used SensL's SPMM3020 and SPMM3035 combined with LYSO, CsI:Tl and BGO, irradiated with99mTc and 137Cs sources The best energy resolution for Tc was 18% and achieved for the SPMM3020, coupled to CsI:Tl at 31V. For 137Cs energy resolution was 10.0% and achieved for the SPMM3020 coupled to CsI(Tl) at 32.5V. © 2010 IEEE.
URI
http://hdl.handle.net/11615/27290
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une sessionS'inscrire
Help Contact
DepositionAboutHelpContactez-nous
Choose LanguageTout DSpace
EnglishΕλληνικά
htmlmap