• English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • español 
    • English
    • Ελληνικά
    • Deutsch
    • français
    • italiano
    • español
  • Login
Ver ítem 
  •   DSpace Principal
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Ver ítem
  •   DSpace Principal
  • Επιστημονικές Δημοσιεύσεις Μελών ΠΘ (ΕΔΠΘ)
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ.
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.
Todo DSpace
  • Comunidades & Colecciones
  • Por fecha de publicación
  • Autores
  • Títulos
  • Materias

Initial results on SiPM array based on a symmetric resistive voltage division readout

Thumbnail
Autor
David, S.; Georgiou, M.; Fysikopoulos, E.; Efthimiou, N.; Paipais, T.; Kefalidis, L.; Loudos, G.
Fecha
2012
DOI
10.1109/NSSMIC.2011.6154380
Materia
Cancer tumor
Energy resolutions
Evaluation board
Experimental evaluation
PET probe
Position signals
Raw images
Resistive voltage
Room temperature
Silicon photomultiplier
Spatial resolution
Voltage output
Ionization
Medical imaging
Nuclear physics
Scintillation
Scintillation counters
Sodium
Visualization
Electric breakdown
Mostrar el registro completo del ítem
Resumen
The aim of this study is to design and apply a symmetric resistive voltage division matrix to read out the compact silicon photomultiplier array (SPMArray2 by SensL) photodetector for possible applications as gamma or PET probes for localization of cancer tumors. We applied a symmetric resistive voltage division circuit, reducing the 16 voltage outputs, which are provided from SensL's evaluation board, to 4 position signals. We acquired raw images and crystal maps from various pixilated scintillators under 99mTc and 22Na excitation, emitting mainly at 140KeV and 511KeV, respectively. The exact values of the resistors as well as the summing amplifiers used in the summation and division stages are given. Moreover, experimental evaluation in terms of energy and spatial resolution is reported. A clear visualization of the discrete 2mm 2 pixilated CsI:Tl scintillator elements under 140keV excitation - with better than 23% energy resolution - was achieved. Raw images of the crystals maps acquired shown visualization of the discrete 1mm 2 CsI:Na scintillator elements under 511keV irradiation. Under 511keV excitation we achieve an energy resolution of ∼35% for BGO and 18% for CsI:Na pixilated scintillators, respectively. All measurements were carried out at room temperature (∼25°C), without additional cooling. © 2011 IEEE.
URI
http://hdl.handle.net/11615/26943
Colecciones
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro
Help Contact
DepositionAboutHelpContacto
Choose LanguageTodo DSpace
EnglishΕλληνικά
htmlmap