Effect of two new cover materials on greenhouse energy consumption and cooling load

Thumbnail
Auteur
Bartzanas, T.; Kitta, E.; Katsoulas, N.; Tsouknidas, A.
Date
2012
Sujet
Air speed profiles
Air temperature
CFD modelling
Greenhouse climate heterogeneity
Relative humidity
Lycopersicon esculentum
Afficher la notice complète
Résumé
The aim of this work was to study the effects of a new polyethylene (PE) film with high reflectance and absorption in near infrared radiation (NIR-PE film) and of a PE film with low transmittance in infrared radiation IR (IR-PE film), on the greenhouse microclimate, energy consumption and on growth and yield of a hydroponic tomato crop. Compared to a common PE film (C-PE), the IR-PE film, had 75% lower transmittance in IR, while the NIR-PE had 78% lower transmittance in IR and 42% higher reflectance in NIR. Films were evaluated experimentally in three similar arched roof greenhouses, two covered with the new covering materials and the third one by a C-PE film. The greenhouse and outside microclimate parameters along with crop growth and production were recorded. During the winter period, no significant differences of air temperature and relative air humidity between the tested greenhouses were found. The air vapour pressure deficit (VPD) values observed were relatively low (i.e below 0.5 kPa) during the night period, leading to condensation over the cover. The total energy consumption was 10% lower in the IR-PE covered greenhouse than in the C-PE covered greenhouse. During the summer period, the air temperature in the greenhouse covered by the NIR-PE was 2°C lower than the air temperature of the C-PE covered greenhouse.
URI
http://hdl.handle.net/11615/26176
Collections
  • Δημοσιεύσεις σε περιοδικά, συνέδρια, κεφάλαια βιβλίων κλπ. [19735]
htmlmap 

 

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsCette collectionPar date de publicationAuteursTitresSujets

Mon compte

Ouvrir une sessionS'inscrire
Help Contact
DepositionAboutHelpContactez-nous
Choose LanguageTout DSpace
EnglishΕλληνικά
htmlmap