Αναζήτηση
Αποτελέσματα 1-2 από 2
Temperature gradients in a partially shaded large greenhouse equipped with evaporative cooling pads
(2003)
The main drawback of greenhouse evaporative cooling systems based on cooling pads and extracting fans is the thermal gradient developed along the direction of the airflow. High-temperature gradients of this type can markedly ...
Greenhouse evaporative cooling: Measurement and data analysis
(2001)
Temperature and humidity gradients were investigated during summer in a commercial greenhouse producing cut roses, equipped with a ventilated cooling-pad system and a half-shaded plastic roof In a steady regime, the cooling ...