Suche
Anzeige der Dokumente 1-4 von 4
THE IMPACT OF INSECT SCREENS AND VENTILATION OPENINGS ON THE GREENHOUSE MICROCLIMATE
(2008)
The objective of this work was to experimentally investigate the influence of vent type (side, roof, or both) and of anti-aphid insect screens on airflow, air temperature, and air vapor pressure deficit distribution in a ...
Pressure field and airflow at the opening of a naturally ventilated greenhouse
(1998)
Direct estimation of airflow at the vent opening by means of differential pressure measurements were performed in a twin-span greenhouse equipped with a continuous vent at the gutter. Application of Bernoulli's equation ...
Influence of an insect screen on greenhouse ventilation
(2002)
The influence of an insect screen on ventilation rate was experimentally investigated in a multispan glass-covered greenhouse equipped with a continuous roof vent, located at the University of Thessaly near volos in the ...
Wind induced air exchange rates in a greenhouse tunnel with continuous side openings
(1996)
To study the influence of wind speed on ventilation rates, experimental trials were carried out in a plastic tunnel with continuous side ventilators. This type of greenhouse is the most representative of Mediterranean and ...