Auflistung Nach Schlagwort "devices"
Anzeige der Dokumente 1-20 von 62
-
An 11- to 15-year clinical outcome study of the Advance Medial Pivot total knee arthroplasty: Pivot knee arthroplasty
(2016)Aims The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the longterm results obtained with this prosthesis by extending ... -
A 13- to 16-year clinical and radiological outcome study of the genesis II cruciate retaining total knee arthroplasty with an oxidised zirconium femoral component
(2019)Purpose: The Genesis II Total Knee Arthroplasty with an oxidized zirconium (OxiniumTM) femoral component (Smith & Nephew, Memphis, TN, USA) was introduced in an attempt to reduce polyethylene wear and osteolysis. Methods: ... -
A 9-Year Outcome Study Comparing Cancellous Titanium-Coated Cementless to Cemented Tibial Components of a Single Knee Arthroplasty Design
(2018)Background: The cemented Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary knee kinematics data and has shown satisfactory long-term outcomes. Methods: We retrospectively evaluated ... -
Automated oxygen delivery in hospitalized patients with acute respiratory failure: A pilot study
(2019)Background and Objectives. Despite its' proven benefits, oxygen therapy may be complicated with potential adverse events such as hypoxemia or hyperoxia-driven hypercapnia. Automated oxygen delivery systems may aid in ... -
Balloon Angioplasty Versus Stenting for the Treatment of Failing Arteriovenous Grafts: A Meta-Analysis
(2018)Purpose: To assess the outcomes of plain balloon angioplasty versus stenting for the treatment of failed or malfunctioning chronic haemodialysis arteriovenous grafts (AVGs). Methods: A systematic search of the literature ... -
The choice of drainage device in complicated glaucomas: Comparing Ahmed and Baerveldt implants
(2019)Background/Aim: Glaucoma is a chronic and progressive optic neuropathy which leads to deterioration of visual function. It is estimated to be the second leading cause of severe vision loss and blindness worldwide. Failure ... -
Comparison of continuous intradermal with simple interrupted suture pattern: an experimental study in dogs
(2020)The aim of the study was to compare incisional wound healing in intradermal and simple interrupted suture patterns. Ten dogs were included. Surgically created skin incisions were apposed with (a) continuous intradermal ... -
Complexity of persistent type II endoleak associated with sac expansion after endovascular abdominal aortic aneurysm repair
(2015)Type II endoleak after endovascular aortic aneurysm repair still remains the Achilles’ heel of the treatment, the source of which regularly is difficult to identify and treat. We present a patient with a persistent type ... -
Considerations regarding embryo culture conditions: From media to epigenetics
(2018)There are numerous reports on embryo culture media and conditions in the laboratory, as the subject is multifaceted and complex, reflecting the variation in practice. In this scoping review, we attempt to approach the topic ... -
Current status of endovascular treatment of aortoenteric fistula
(2017)Aortoenteric fistula (AEF) is one of the most challenging diagnostic and therapeutic entities in vascular surgery. AEF can occur either primarily involving the aorta and the gastrointestinal tract or, more commonly, secondary ... -
Devices and tasks involved in the objective assessment of standing dynamic balancing – A systematic literature review
(2017)Background: Static balancing assessment is often complemented with dynamic balancing tasks. Numerous dynamic balancing assessment methods have been developed in recent decades with their corresponding balancing devices and ... -
DIANA-tarbase and DIANA suite tools: Studying experimentally supported microRNA targets
(2016)microRNAs (miRNAs) are short non-coding RNAs (~22 nts) present in animals, plants, and viruses. They are considered central post-transcriptional regulators of gene expression and are key components in a great number of ... -
Double fixation for abdominal aortic aneurysm repair using AFX body and Endurant proximal aortic cuff: Mid-term results
(2017)Our goal was to evaluate the use of an AFX main body combined with an Endurant proximal aortic cuff to treat selected patients with an abdominal aortic aneurysm (AAA) associated with anatomical challenges, such as a small ... -
Early outcomes of the t-Branch off-the-shelf multi-branched stent graft in 542 patients for elective and urgent aortic pathologies: A retrospective observational study
(2021)Objective: The t-Branch, a standardized off-the-shelf multi-branched stent graft has been used for the treatment of elective and urgent cases in aortic disease. The aim of this study was to assess the early outcomes in ... -
The effect of covering material on the yield, quality and chemical composition of greenhouse-grown tomato fruit
(2019)BACKGROUND: During the last few decades, greenhouse technology for horticultural crops has focused on retaining optimum conditions within the greenhouse environment that could allow for a compromise between maximum yields ... -
Efficacy and Safety of Heparinization before Deployment of Endograft for Blunt Traumatic Aortic Injury in Severely Injured Patients
(2021)Background: The administration of unfractionated heparin (UFH) during endovascular repair of blunt traumatic aortic injury (BTAI) is controversial. The aim of the study is to report the early outcomes of patients undergoing ... -
Endograft Specific Haemodynamics After Endovascular Aneurysm Repair: Flow Characteristics of Four Stent Graft Systems
(2019)Objectives: The implication of haemodynamics in the occurrence of complications after endovascular aneurysm repair (EVAR) has been raised in the literature. Different aortic stent graft configurations may lead to different ... -
Endovascular aneurysm repair in patients with a wide proximal aortic neck: A systematic review and meta-analysis of comparative studies
(2019)INTRODUCTION: The aim was to investigate the impact of wide proximal aortic diameter on outcome after standard endovascular repair (sEVAR) of infrarenal abdominal aortic aneurysms. EVIDENCE ACQUISITION: A systematic search ... -
Endovascular treatment of complex abdominal and thoracoabdominal type IV aortic aneurysms with fenestrated technology
(2017)The establishment use of fenestrated and branched devices to treat complex aortic aneurysms as a first-line management option has been previously reported. This article reviews the current literature of the use of fenestrated ...