• Anatomical variations of the foramen transversarium in cervical vertebrae: findings, review of the literature, and clinical significance during cervical spine surgery 

      Zibis A.H., Mitrousias V., Baxevanidou K., Hantes M., Karachalios T., Arvanitis D. (2016)
      Purpose: To describe certain anatomical variations of the foramen transversarium, in spine cervical vertebrae in a contemporary specimen of an Indo-European population and approach their clinical importance during cervical ...
    • Restoration of the degenerated cervical intervertebral space: how much should we distract? A magnetic resonance imaging study 

      Fyllos A.H., Zibis A.H., Banios K., Mitrousias V.D., Karantanas A.H., Markou A.S., Mangiavini L., Luceri F. (2020)
      The aim of the study was to quantify normal cervical disc space measurements and to generate a normal values’ database. Furthermore, during operative restoration of a degenerated intervertebral disc, it is difficult to ...
    • The Role of Gait Analysis in the Evaluation of Patients with Cervical Myelopathy: A Literature Review Study 

      Siasios I.D., Spanos S.L., Kanellopoulos A.K., Fotiadou A., Pollina J., Schneider D., Becker A., Dimopoulos V.G., Fountas K.N. (2017)
      Background Gait analysis represents one of the newest methodologies used in the clinical evaluation of patients with cervical myelopathy (CM). Objective To describe the role of gait analysis in the clinical evaluation of ...
    • The role of steroid administration in the management of dysphagia in anterior cervical procedures 

      Siasios I., Fountas K., Dimopoulos V., Pollina J. (2018)
      Dysphagia is a common postoperative symptom for patients undergoing anterior cervical spine procedures. The purpose of this study is to present the current literature regarding the effect of steroid administration in ...
    • Test–re-test reliability and concurrent validity of cervical active range of motion in young asymptomatic adults using a new inertial measurement unit device 

      Chalimourdas A., Dimitriadis Z., Kapreli E., Strimpakos N. (2021)
      Objectives: Cervical range of motion (CROM) is one of the first things evaluated in cervical disorders. DyCare-Lynx is an inertial measurement unit device that was recently designed to measure CROM. Therefore, the objectives ...
    • Variations in management of A3 and A4 cervical spine fractures as designated by the AO Spine Subaxial Injury Classification System 

      Kweh B.T.S., Tee J.W., Muijs S., Oner F.C., Schnake K.J., Benneker L.M., Vialle E.N., Kanziora F., Rajasekaran S., Schroeder G., Vaccaro A.R., Grin A., Abdelgawaad A.S., Zubairi A.J., Castillo A., Lezica A.V., Ramieri A., Guiroy A., Grundshtein A., Godinho A., Jr, Henine A., Pershin A.A., Athanasiou A., Zarate-Kalfopulos B., Benzarti S., Bernucci C., Rebholz B.J., Direito-Santos B., Costa B.L., Saciloto B., Majer C., Tannoury C., Cheng C., Cheung J.P.Y., Konrads C., Jetjumnong C., Chung C.K., Popescu E.C., Kilinçer C., Harrism C.B., Steiner C.D., Igualada C., Perovic D., Picazo D.R., Falcone L.D.O., Gopalakrishnan D., Ankit D., Tokala D.P., Karmacharya B., Lotan R., Shoaib M., Russo S., Viswanadha A.K., Garg B., Uribe N.D., Medina F., Subbiah J., Alsammak W., Mandizvidza V., Atan A.A., Barani R., Sámano H.V., Pemovska E.S., Hinojosa F.C.L., Fang T., Landriel F., Sartor F.D., De Oliveira Ferreira M.V., Fiorenza V., Mannara F.A., Franz S., Freedman B.A., Grozman S.A.M., Espinosa G., Ricciardi G.A., Ponnusamy G., Amadou H.A., Romero I., Rutges J., Harrop J., Sauri-Barraza J.-C., Sharma J.K., Arbatin J.J.F., Jr, Milano J.B., Francis J.J., Li Tat J.C., Vahl J., Corredor J.A., Morais J.M., Guasque J., Koerner J., Johnny D., Ron J.R.P., Delgado-Fernandez J., Montoya J.E.M., Lourido J., Kaen A., Özdener K.M., Margetis K., Paterakis K., Cari L.L., Fu L., Dawoud A., Luna L.M., Alkharsawi M., Diez-Ulloa M.-A., García-Pallero M.A., Pluderi M., Gruenberg M., Valacco M., Ganau M., Estefan M.M., Rodríguez L.M.D., Miyakoshi N., Elshamly M., Khattab M.F., Smith S.R., Abeid M., Garfinkel I., Nicassio N., Neves N., Acosta O.C.M., Bazán P.L., Pereira P., Lim P., Pritchard P.R., Bhatt P., Kundangar R., Vieira R.S., Rodrigues-Pinto R., Panchal R.R., Llombart-Blanco R., Rosas R.A.R., Manilha R., Yurac R., Diniz S., Wagner S.C., Fuego S., Ramakrishnan S., Demiröz S., Hackla S., Shariati B., El-Sharkawi M., Sorimachi Y., Corluka S., Yuh S.-J., Benzakour T., ElHewala T., Suri T., Cawley D.T., Toluse A., Valdez C., Abdul W., Hassan W., Robinson Y., Hickman Z.L., Amin M.Z.H.M., Guerra O.G., Klezl Z., the AO Spine Subaxial Injury Classification System Validation Group (2022)
      OBJECTIVE Optimal management of A3 and A4 cervical spine fractures, as defined by the AO Spine Subaxial Injury Classification System, remains controversial. The objectives of this study were to determine whether significant ...
    • Variations of transverse foramina in cervical vertebrae: what happens to the vertebral artery? 

      Zibis A., Mitrousias V., Galanakis N., Chalampalaki N., Arvanitis D., Karantanas A. (2018)
      Purpose: The purpose of this study is to examine variations of the foramen transversarium and the vertebral artery in computed tomography angiographies (CTa) of the cervical spine, investigate their coexistence, and present ...