Εμφάνιση απλής εγγραφής

dc.creatorYin J., Nakas C.T., Tian L., Reiser B.en
dc.date.accessioned2023-01-31T11:37:54Z
dc.date.available2023-01-31T11:37:54Z
dc.date.issued2018
dc.identifier10.1177/0962280217740787
dc.identifier.issn09622802
dc.identifier.urihttp://hdl.handle.net/11615/80891
dc.description.abstractThis article explores both existing and new methods for the construction of confidence intervals for differences of indices of diagnostic accuracy of competing pairs of biomarkers in three-class classification problems and fills the methodological gaps for both parametric and non-parametric approaches in the receiver operating characteristic surface framework. The most widely used such indices are the volume under the receiver operating characteristic surface and the generalized Youden index. We describe implementation of all methods and offer insight regarding the appropriateness of their use through a large simulation study with different distributional and sample size scenarios. Methods are illustrated using data from the Alzheimer's Disease Neuroimaging Initiative study, where assessment of cognitive function naturally results in a three-class classification setting. © 2017, © The Author(s) 2017.en
dc.language.isoenen
dc.sourceStatistical Methods in Medical Researchen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85042563928&doi=10.1177%2f0962280217740787&partnerID=40&md5=246c92cd800364061da4eb25b50ae6e0
dc.subjectAlzheimer diseaseen
dc.subjectArticleen
dc.subjectcognitionen
dc.subjectconfidence intervalen
dc.subjectdisease markeren
dc.subjectgeneralized Youden indexen
dc.subjectneuroimagingen
dc.subjectsample sizeen
dc.subjectsimulationen
dc.subjectstatistical parametersen
dc.subjectvolumes under receiver operating characteristic surfaceen
dc.subjectAlzheimer diseaseen
dc.subjectarea under the curveen
dc.subjectbiostatisticsen
dc.subjectcomputer simulationen
dc.subjectdiagnostic imagingen
dc.subjecthumanen
dc.subjectnonparametric testen
dc.subjectproceduresen
dc.subjectproportional hazards modelen
dc.subjectreceiver operating characteristicen
dc.subjectbiological markeren
dc.subjectAlzheimer Diseaseen
dc.subjectArea Under Curveen
dc.subjectBiomarkersen
dc.subjectBiostatisticsen
dc.subjectComputer Simulationen
dc.subjectConfidence Intervalsen
dc.subjectHumansen
dc.subjectNeuroimagingen
dc.subjectProportional Hazards Modelsen
dc.subjectROC Curveen
dc.subjectStatistics, Nonparametricen
dc.subjectSAGE Publications Ltden
dc.titleConfidence intervals for differences between volumes under receiver operating characteristic surfaces (VUS) and generalized Youden indices (GYIs)en
dc.typejournalArticleen


Αρχεία σε αυτό το τεκμήριο

ΑρχείαΜέγεθοςΤύποςΠροβολή

Δεν υπάρχουν αρχεία που να σχετίζονται με αυτό το τεκμήριο.

Αυτό το τεκμήριο εμφανίζεται στις ακόλουθες συλλογές

Εμφάνιση απλής εγγραφής