Video Laryngoscopy Improves Intubation Times With Level C Personal Protective Equipment in Novice Physicians: A Randomized Cross-Over Manikin Study
Data
2021Language
en
Soggetto
Abstract
Background: The use of video laryngoscopes by novice physicians may improve first-pass success rates compared with direct laryngoscopy. Objective: The aim of the present study was to assess whether time to intubation, number of laryngoscopy attempts, and first-pass success rate during laryngoscopy with the video laryngoscope or conventional Macintosh laryngoscope are affected by personal protective equipment (PPE) donning. Methods: Seventy inexperienced physicians were randomly assigned to video laryngoscope or Macintosh groups and were instructed to perform intubation with both devices on a manikin, using PPE or a standard uniform. The primary outcomes were insertion time, number of laryngoscopy attempts, and first-pass success rates for each device with or without donning PPE. Results: In the Macintosh group, significantly less time was needed for the first successful intubation without PPE vs. with PPE (12.17 ± 3.69 s vs. 24.07 ± 5.09 s, respectively; p < 0.0001). On the other hand, such difference was not observed in the video laryngoscope group (14.99 ± 3.01 s vs. 14.01 ± 3.35 s, respectively; p = 0.07). With PPE, the first-pass success rate was significantly higher in the video laryngoscope group [41 (58.6%) vs. 66 (94.3%), p < 0.001]. The use of the video laryngoscope resulted in a significant decrease in insertion time compared with the Macintosh blade (14.01 ± 3.35 s vs. 24.07 ± 5.09 s, respectively; p < 0.0001). Conclusion: First-pass success and insertion time with the video laryngoscope were not affected by PPE donning. However, both were negatively affected with the Macintosh laryngoscope. © 2021 Elsevier Inc.
Collections
Related items
Showing items related by title, author, creator and subject.
-
AMBIENT DOSE EQUIVALENT RECEIVED at 15 MV LINAC ENVIRONMENTS DUE to PHOTONEUTRONS CONTAMINATION
Vagena E., Katsaras P., Theodorou K., Stoulos S. (2018)Mapping of the photoneutron spectrum and flux performed at several positions over the treatment table of a 15 MV medical linac. Neutron activation technique has been applied to obtain the neutron spectra in the mixed I3 ... -
Numerical study of mechanically ventilated broiler house equipped with evaporative pads
Fidaros D., Baxevanou C., Bartzanas T., Kittas C. (2018)One of the important factors to improve the broiler production is the provision of an optimum indoor environment (air quality, temperature, humidity, air velocity, gases and PMs concentration) with lower possible cost. The ... -
Occupational noise vibration & air pollutants fluctuation inside the toll booths in the athens ring motorway network: "Attiki Odos"
Vogiatzis, K.; Eliou, N. (2007)Attikes Diadromes S.A (a company ensuring the "Maintenance - Operation and Exploitation of the motorway Elefsina - Stavros - Spata Airport & West Peripheral Ymittos Avenue "), in close cooperation with the University of ...