dc.description.abstractThis paper presents an experimental investigation on the use of textile-reinforced mortar (TRM) jackets as a means of improving the out-of-plane performance of masonry infill walls in reinforced concrete (RC) frames during natural or humanmade catastrophic events (e.g., blasts, earthquakes). The experimental program included testing of six half-scale, single-story masonry-infilled RC frames. All specimens were subjected to out-of-plane monotonic loading with the load being distributed at four points on the infill's body. Two specimens were tested without receiving any retrofitting, thus serving as reference specimens; one with single-wythe and one with double-wythe infill wall. The remaining four specimens were first retrofitted with carbon-fiber TRM jackets and then tested to failure. The examined parameters included: (1) the connection configuration between the masonry infill wall and the surrounding RC frame members and (2) the thickness of the wall. It was found that the out-of-plane performance was dramatically improved in all cases of retrofitted walls, with the examined parameters playing a crucial role in certain aspects of the wall's behavior. Overall, the risk of collapse was drastically mitigated when the walls were connected to the RC frame, thus enhancing the resilience of masonry-infilled RC buildings subjected to humanmade or natural catastrophic events. © 2018 This work is made available under the terms of the Creative Commons Attribution 4.0 International license,.en
dc.language.isoenen
dc.sourceJournal of Composites for Constructionen
dc.source.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85058301891&doi=10.1061%2f%28ASCE%29CC.1943-5614.0000911&partnerID=40&md5=9dfc97310d7429c467976d3a5bd131c0
dc.subjectCarbon fibersen
dc.subjectInfill drillingen
dc.subjectMortaren
dc.subjectReinforced concreteen
dc.subjectRetrofittingen
dc.subjectSoftware testingen
dc.subjectStrengthening (metal)en
dc.subjectTextilesen
dc.subjectCementitious matricesen
dc.subjectIn-filled framesen
dc.subjectInfillen
dc.subjectMasonryen
dc.subjectOut-of planeen
dc.subjectTextile-reinforced mortarsen
dc.subjectWalls (structural partitions)en
dc.subjectAmerican Society of Civil Engineers (ASCE)en
dc.titleOut-of-Plane Strengthening of Masonry-Infilled RC Frames with Textile-Reinforced Mortar Jacketsen