Mitral and tricuspid annuloplasty ring dehiscence: A systematic review with pooled analysis
Ημερομηνία
2021Γλώσσα
en
Λέξη-κλειδί
Επιτομή
OBJECTIVES: Mitral and tricuspid ring annuloplasty dehiscence with consequent recurrent valve regurgitation is a rare but challenging procedural failure. The incidence and predisposing risk factors for annuloplasty ring dehiscence include technical and pathological ones. METHODS: A systematic database search with pooled analysis was conducted of original articles that only included dehiscence rate of mitral and tricuspid ring in EMBASE, MEDLINE, Cochrane database and Google Scholar, from inception to November 2020. The outcomes included were dehiscence rate in mitral and tricuspid, type of ring implanted, dehiscence rate by pathology and by ring size and shape. RESULTS: Our search yielded 821 relevant studies. Thirty-three studies met the inclusion criteria with a total of 10 340 patients (6543 mitral, 1414 tricuspid) of which 87 (mitral) and 30 (tricuspid) had dehiscence. Overall, dehiscence rate was 1.43%, diagnosed at a median of 4.5 ± 1.0 months postoperatively. A significant difference in mitral dehiscence rate was found by ring type (semi-rigid 1.86%, rigid 2.32%; flexible 0.43%; P < 0.001). There was no significant difference in rate of dehiscence by ring size (P = 0.067) and shape in mitral (P = 0.281) but there was higher dehiscence rate in ischaemic compared to non-ischaemic mitral regurgitation (3.91% vs 1.63%; P = 0.022). Among tricuspid studies, 9 of 10 studies did not report any dehiscence. CONCLUSIONS: Although rigid, semi-rigid and flexible annuloplasty rings provide acceptable valve repair outcomes, mitral annuloplasty ring dehiscence is clinically more common among rigid rings. Understanding the multifactorial nature of ring dehiscence will help in identifying the patients at high risk and improve their clinical outcomes. © 2021 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery.
Collections
Related items
Showing items related by title, author, creator and subject.
-
An 11- to 15-year clinical outcome study of the Advance Medial Pivot total knee arthroplasty: Pivot knee arthroplasty
Karachalios Th., Varitimidis S., Bargiotas K., Hantes M., Roidis N., Malizos K.N. (2016)Aims The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the longterm results obtained with this prosthesis by extending ... -
Genesis 1 posterior cruciate-retaining total knee arthroplasty with asymmetric tibial tray: An 18-to-26-year long-term clinical outcome study
Georgaklis V.A., Karachalios T., Makridis K.G., Badras S.L., Palaiochorlidis I.S., Malizos K.N., Badras L.S. (2019)Background: To present the long-term clinical and radiological outcomes of the Genesis I posterior cruciate-retaining total knee arthroplasty (TKA) (Smith & Nephew Orthopaedics, Memphis, TN, USA) (one of the first designed ... -
A 13- to 16-year clinical and radiological outcome study of the genesis II cruciate retaining total knee arthroplasty with an oxidised zirconium femoral component
Papasoulis E., Karachalios T. (2019)Purpose: The Genesis II Total Knee Arthroplasty with an oxidized zirconium (OxiniumTM) femoral component (Smith & Nephew, Memphis, TN, USA) was introduced in an attempt to reduce polyethylene wear and osteolysis. Methods: ...